Related Experiment Video
Updated: Dec 30, 2025

Introducing an Angle Adjustable Cutting Box for Analyzing Slice Shear Force in Meat
Published on: April 26, 2013
Sous-vided Restructured Goat Steaks: Process Optimized by Thermal Inactivation of Listeria monocytogenes and Their
Pussadee Tangwatcharin1, Supaluk Sorapukdee1, Kamonthip Kongsrirat1
1Department of Animal Production Technology and Fisheries, Faculty of Agricultural Technology, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.
Abstract:
The thermal-death times of Listeria monocytogenes were determined in inoculated restructured goat steak at 60°C, 65°C, and 70°C of sous-vide temperatures. D-values of L. monocytogenes in inoculated restructured goat steak ranged from 7.27 min at 60°C to 0.46 min at 70°C. Times need to yield at least a 6 log reduction of L. monocytogenes at their temperatures for this product were 47, 12, and 3 min, respectively. After sous-vide, all microbial counts in non-inoculated samples were not detectable, except the aerobic and anaerobic mesophilie and lactic acid bacteria counts were lower than 2 Log CFU/g. For sous-vided and grilled sous-vided samples, sous-vide loss and surface shrinkage were the lowest in samples sous-vided at 60°C for 47 min (p<0.05). These samples demonstrated the lowest CIE L*, shear force, hardness, gumminess and chewiness and the highest CIE a* and hue angle (p<0.05). Therefore, sous-vide at 60°C for 47 min provided convenient ready-to-cook restructured goat steak for microbiology safety and optimization of physicochemical quality.
More Related Videos
04:40The Cultivation, Growth, and Viability of Lactic Acid Bacteria: A Quality Control Perspective
Published on: June 16, 2022
07:46Author Spotlight: Improving Beef Cattle Nutrition and Production with a Focus on Feed Efficiency and Meat Quality Traits Through Advanced Biochemical and Molecular Assays
Published on: July 12, 2024
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Temperature
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Tissue Homogenization and Cell Lysis
Mechanical methods of tissue homogenization
These methods rely on applying external physical force to disrupt...