Reliability of single breath hold three-dimensional cine kat-ARC for the assessment of biventricular dimensions and
Giuseppe Muscogiuri1, Marco Gatti2, Serena Dell'Aversana3
1Centro Cardiologico Monzino, IRCCS, Milan, Italy.
Purpose:
To assess the accuracy and reproducibility of 3D-cine k-adaptative-t-autocalibrating reconstruction for cartesian sampling (3D cine kat-ARC) for quantification of biventricular volumes, ejection fraction and LV mass in clinical practice.
Method:
74 patients underwent cardiac magnetic resonance for clinical indications. In the whole population 3D cine kat-ARC and 2D cine bSSFP images were acquired on short axis view. Subsequently, the population was divided in three subgroups (dilated, hypetrophic, other phenotypes). Two experienced observers performed analysis of volumes, biventricular function and left ventricular mass in the overall population and subgroups using an off-line workstation. Statistical analysis was performed using Student's t-test, linear regression and Bland-Altman plot, correlation coefficient η2 and the intraclass correlation coefficient (ICC). A cut-off value of p < 0.05 was considered statistically significant.
Results:
Biventricular volumes, function and left ventricular mass evaluated with 3D cine kat-ARC sequences did not show any significant difference compared to 2D bSSFP sequences in the overall population (p > 0.05). Bland-Altman analysis showed limited bias and narrow limits of the agreement for all measurements in overall population. Subgroup analysis showed a statistically significant difference (p = 0.04) for left ventricular ejection fraction (LVEF) in patients with a dilated phenotype; showing a minimum overestimation tendency for 3D cine kat ARC (2D cine bSSFP LVEF = 46.44 ± 15.83% vs 3D cine kat-ARC LVEF = 48.36 ± 16.50 %).
Conclusions:
3D cine kat-ARC 3D sequences allow an accurate evaluation of biventricular volumes and function in a single breath hold.
More Related Videos
08:223D Cine Magnetic Resonance Imaging of Respiratory Motion in Mechanically Ventilated Mice and Rats
Published on: September 19, 2025
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies