Related Experiment Video
Updated: Dec 30, 2025

Method to Measure Tone of Axial and Proximal Muscle
Published on: December 14, 2011
Tremoroton, a new free online platform for tremor analysis
Felipe Vial1,2, Patrick McGurrin1, Thomas Osterholt1
1Human Motor Control Section, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD, USA.
Objective:
The electrophysiological classification of tremors can be a key element in the diagnosis and can facilitate treatment of a patient with tremor; however, the ability to conduct electrophysiological studies of tremor is not widely available. The purpose of this study was to develop and validate a free online platform for tremor analysis.
Methods:
An online platform for tremor analysis was developed using "R" language; called "Tremoroton". For validation, we compared the frequency estimation of the tremor obtained with Tremoroton compared with a commercially available software in a cohort of 20 patients (10 with essential tremor and 10 with Parkinson diagnosis), comparing the activity recorded on the accelerometer, extensor carpi radialis and flexor carpi radialis EMG. An intraclass correlation coefficient was used for the comparison.
Results:
The final version of tremoroton is now online. It allows reading up to 6 channels, and will do time, frequency, time-frequency analysis and calculate coherence. We demonstrated a high correlation in frequency measurements (0.97 (0.945-0.984, 95% IC) for the accelerometers, 0.98 (0.977-0.994, 95% IC) for the extensor carpi radialis EMG, and 0.99 (0.987-0.997, 95% IC) for the flexor carpi radialis EMG) when compared to a commercial software.
Conclusion:
We were able to develop and validate a free online platform for tremor analysis.
Significance:
Making this tool available should help expanding tremor analysis techniques from research to the clinical setting.
Related Concept Videos
Torque Free Motion
Torsional Pendulum
As long as the rigid body's angular displacement is small, its oscillation can be modeled as a linear angular oscillation. The amplitude of the oscillation is an angle. The role of mass is played...
Physical Pendulum
When dealing with complicated systems, the mass moment of inertia is an important parameter, as it...
Seizures: Classification
Seizures are typically classified into two main categories: focal and generalized seizures.
Focal Seizures
Focal seizures originate from specific regions of the brain. These seizures are further sub-classified into two types: