AMEBaS: Automatic Midline Extraction and Background Subtraction of Ratiometric Fluorescence Time-Lapses of Polarized Single Cells
Published on: June 23, 2023
747
Automatic Background Removal and Correction of Systematic Error Caused by Noise Expecting Bio-Raman Big Data Analysis
Akunna Francess Ujuagu1, Ziteng Wang1, Shin-Ichi Morita2
1Graduate School of Science, Tohoku University, 6-3 Aramaki-Aza-Aoba, Aoba, Sendai, 980-8578, Japan.
Summary
Automated background removal in Raman spectroscopy is improved by a new method correcting measurement noise. This technique enhances accuracy and effectiveness for big data analysis.
Area of Science:
- Analytical Chemistry
- Spectroscopy
- Data Science
Background:
- Spectral data preprocessing, including background removal, is essential for Raman spectroscopy.
- Automated methods are needed to handle large datasets efficiently.
Purpose of the Study:
- To propose a practical method for correcting systematic errors caused by noise in spectral measurements.
- To enhance the accuracy and effectiveness of automated background removal in Raman spectroscopy.
Main Methods:
- Developed an automated background removal method considering the shortest spectrum length via scaling factor adjustment.
- Implemented a novel correction for systematic errors arising from measurement noise.
Main Results:
- The proposed noise correction method proved effective and accurate.
- The enhanced method improves the overall performance of automatic background removal.
Conclusions:
- The developed noise correction technique offers a practical solution for improving spectral data quality.
- This advancement facilitates more reliable advanced spectral analysis in Raman spectroscopy.
More Related Videos
Related Concept Videos
Systematic Error: Methodological and Sampling Errors
8.3K
In the case of systematic errors, the sources can be identified, and the errors can be subsequently minimized by addressing these sources. According to the source, systematic errors can be divided into sampling, instrumental, methodological, and personal errors.
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
8.3K
Random and Systematic Errors
14.2K
Scientists always try their best to record measurements with the utmost accuracy and precision. However, sometimes errors do occur. These errors can be random or systematic. Random errors are observed due to the inconsistency or fluctuation in the measurement process, or variations in the quantity itself that is being measured. Such errors fluctuate from being greater than or less than the true value in repeated measurements. Consider a scientist measuring the length of an earthworm using a...
14.2K
NMR Spectrometers: Resolution and Error Correction
983
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
983