An automated assessment system of limits of detection and quantitation in gradient high-performance liquid
Akira Kotani1, Hideki Hakamata1, Yuzuru Hayashi2
1School of Pharmacy, Tokyo University of Pharmacy and Life Sciences, 1432-1 Horinouchi, Hachioji, Tokyo 192-0392, Japan.
Abstract:
A previous paper of this series of study put forward a basic model of an automated system for predicting detection limits and showed its application to a simple example of isocratic high-performance liquid chromatography (HPLC). This paper describes an expansion of the basic system into gradient HPLC. The most serious problem with the expansion is a long-term variation in backgrounds, called gradient baseline drifts, which in theory cannot be covered by a noise model (stationary random process) of the original system. This paper demonstrates that the above problem can be solved with modifying a parametrization procedure of the noise model. The essential role of the system is to predict the standard deviation (SD) of measurements at low concentrations from a chromatogram without repeated measurements of real samples. Laboratory-made software enables the automated assessment of the limits of detection and quantitation for each of chromatographically separated signals in a single run. Simulated background noise which consists of the stationary noise model with linear slopes is used to confirm the accuracy and reproducibility of the automated prediction. A gradient HPLC determination for cefaclor is taken as an example. The parametrization modification improves the correlation coefficient, r2, between the observed and theoretical distributions of the area measurements from 0.373 to 0.966. The statistical confidence levels of the theoretically predicted relative SDs for cefaclor were verified by comparing them with those obtained by repeated experiments (r2 = 0.989). The limits of detection (= 3.3 × SD = 18.0 µg/L) and quantitation (= 10 × SD = 54.7 µg/L) for cefaclor have signal-to-noise ratios close to the commonly adopted values, 3 and 10, respectively.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
10:21Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...