Related Experiment Video
Updated: Dec 22, 2025

Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Metal Ion Accumulation on Denture Teeth Following Exposure to Chlorhexidine and Different Drinks: A Spectrometric
Gerard A Fischer1, Georgios E Romanos1
1Laboratory for Periodontal-, Implant-, Phototherapy (LA-PIP), School of Dental Medicine, Department of Periodontology, Stony Brook University, Stony Brook, NY 11794, USA.
Abstract:
Denture teeth are used for removable prostheses and implant-supportive restorations. The purpose of this study was to analyze the surface of artificial teeth following exposure to different liquids. Mechanical wear and the cleaning of artificial teeth were also investigated. Two groups of resin teeth were used; original surface (Group A) and surface abrasion/wear (Group B). The teeth were exposed for 24 h to water (control), cola (Group 1), coffee (Group 2), tea (Group 3), chlorhexidine (Group 4), and red wine (Group 5). Baseline measurements of liquids were taken. An x-ray fluorescence spectrometric analysis was performed. Data were evaluated using semi-quantitative descriptive analysis. The data showed approximate increases of peak intensity for Group A1-2-fold Fe, 2-fold Ni, 2.2-fold Zn; for Groups A2 and A3- less than 1.5-fold Fe, Ni, and Zn. Group B yielded similar results; however, the increases in Fe, Ni, and Zn were significantly higher in Groups 1 and 2 (ranged 2-4-fold increases in intensity). Group B3 showed little increase in Fe, Ni, and Zn. Groups A4 and A5 showed intensity increases for Zn. Groups A1-A5 showed reductions in intensity following 30 s of cleaning. A pronounced accumulation of iron, nickel, and zinc was found after exposure to liquids, especially when artificial teeth were worn down. Peak intensities were reduced following 30 s of brushing.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Complexometric Titration: Ligands
Qualitative Analysis
For instance, group IV...
Extraction: Advanced Methods
EDTA: Chemistry and Properties
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...

