Related Experiment Video
Updated: Sep 17, 2025

Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Development and application of a solid-phase microextraction gas cromatography mass spectrometry method for analysing
Serena Scortichini1, Maria Chiara Boarelli2, Mauro Castello2
1School of Science and Technology, Chemistry Division, University of Camerino, Via S. Agostino 1, Camerino, 62032, Italy.
Abstract:
In the last decades, there is more awareness on the impact on human health of pollutants emitted during cooking processes, both from commercial and from domestic activities. In this study, a new method exploiting solid-phase microextraction and gas chromatography coupled to mass spectrometry (SPME-GC-MS) was developed to analyse the volatile organic compounds (VOCs) emitted during cooking. The air above the cooking plate was sampled using a polyethylene terephthalate olfactometric bag that allows to transport the sample to the instrument location and to perform the SPME extraction of the sampled air. The efficiency of different extraction systems and different extraction times (1, 8, 16, and 24 h) was evaluated in order to obtain sufficient sensitivity. Thus, the proposed system, combining the use of olfactometric bags and SPME-GC-MS, was applied for the first time to study VOCs emitted during cooking allowing to perform the analysis, even on samples produced in sites far from the instrument location, in an easy way and with instrumentations available in most of laboratories. Then, the method was applied to assess the efficiency of odour filters used in common kitchen hoods, using deep frying of potatoes in sunflower oil as cooking model system. VOCs were analysed in the air before and after passage through the filter, calculating then percentages of dejection for the different classes of VOCs that resulted to be in the range 31-77%.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Volatilization
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...