Investigation on Surface Tilting in the Failure Process of Shallow Landslides
Shifan Qiao1, Chaobo Feng1, Pengkun Yu1
1Department of Civil Engineering, Central South University, Changsha 410075, China.
Abstract:
In recent decades, early warning systems to predict the occurrence of landslides using tilt sensors have been developed and employed in slope monitoring due to their low cost and simple installation. Although many studies have been carried out to validate the efficiency of these early warning systems, few studies have been carried out to investigate the tilting direction of tilt sensors at the slope surface, which have revealed controversial results in field monitoring. In this paper, the tilting direction and the pre-failure tilting behavior of slopes were studied by performing a series of model tests as well as two field tests. These tests were conducted under various testing conditions. Tilt sensors with different rod lengths were employed to investigate the mechanism of surface tilting. The test results show that the surface tilting measured by the tilt sensors with no rods and those with short rods located above the slip surface are consistent, while the tilting monitored by the tilt sensors with long rods implies an opposite rotational direction. These results are important references to understand the controversial surface tilting behavior in in situ landslide monitoring cases and imply the correlation between the depth of the slip surface of the slope and the surface tilting in in situ landslide monitoring cases, which can be used as the standard for tilt sensor installation in field monitoring.
More Related Videos
06:55Kinematic History of a Salient-recess Junction Explored through a Combined Approach of Field Data and Analog Sandbox Modeling
Published on: August 5, 2016
10:30Soil Lysimeter Excavation for Coupled Hydrological, Geochemical, and Microbiological Investigations
Published on: September 11, 2016
Related Concept Videos
Design Example: Maintaining Level of an Embankment
Slump Test
Concrete is poured into the mold in three layers to conduct the test. Each layer is compacted 25 times with a steel tamping rod, which has a five-eighths-inch diameter and a rounded end, to ensure even distribution and eliminate...
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Errors in Taping
Taping Over Different Ground Profiles
Unsoundness of Aggregate due to Volume Change