Does the application of Opsite⋄ Flexigrid⋄ occlude the oxygen saturation readings in healthy individuals using the
A Beaumont1, L McSorley1, M Matthews1
1Centre for Regenerative Medicine and Devices, University of Brighton, 49 Darley Road, Eastbourne, BN20 7UR, UK.
Background:
A proportion of people who have been diagnosed with peripheral arterial disease and diabetes mellitus will be susceptible to chronic wounds. Oxygen is vital for wound healing, so oxygen measurements should to be taken as predictive values for wound healing in patients. When measuring oxygen at the wound bed, there is potentially a risk of cross-infection if no protective barrier is used; and skin stripping if an adhesive barrier is used on the wound bed. This cross sectional within subject repeated measures pilot study, aims to determine if the application of opsite film, as an infection control measure, in one or two layers, impacts on tissue oxygenation readings obtained when using the MoorVMS-OXY.
Methods:
Mean oxygen saturation percentages were measured from 29 limbs of 18 healthy participants. Oxygen saturation was measured for 20 s and analysed at the first metatarsophalangeal joint using no film, one and two layers using the MoorVMS-OXY. A one-way repeated ANOVA with a Bonferroni post hoc test was performed to test for statistically significant differences between the values of the three parameters and multiple pairwise comparisons was completed.
Results:
Amongst the three layers, there was a statistically significant difference in oxygen saturation between the two layers of Opsite Flexigrid and none; and also between the two layers of Flexigrid and single layer (p < 0.05). It was also established that there was no statistically significant difference between the single layer of Opsite Flexigrid and no Flexigrid layer (p > 0.05).
Conclusions:
The results imply that one layer of Opsite Flexigrid is a suitable protective barrier to use when establishing capillary bed oxygen perfusion with the MoorVMS-OXY. However, the application of two Opsite Flexigrid layers, to prevent skin stripping, decreases the recorded values of oxygen saturation percentages significantly, therefore providing inaccurate results. Indicating that a double layer cannot be used over ulceration sites if measuring oxygen levels at the wound bed.
More Related Videos
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Oxygen Transport in the Blood
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...