Related Experiment Video
Updated: Dec 20, 2025

An Application for Pairing with Wearable Devices to Monitor Personal Health Status
Published on: February 3, 2022
Mobile Personal Health Care System for Noninvasive, Pervasive, and Continuous Blood Pressure Monitoring: Development
Luis J Mena1, Vanessa G Félix1, Rodolfo Ostos1
1Academic Unit of Computing, Master Program in Applied Sciences, Universidad Politecnica de Sinaloa, Mazatlan, Mexico.
Background:
Smartphone-based blood pressure (BP) monitoring using photoplethysmography (PPG) technology has emerged as a promising approach to empower users with self-monitoring for effective diagnosis and control of hypertension.
Objective:
This study aimed to develop a mobile personal health care system for noninvasive, pervasive, and continuous estimation of BP level and variability, which is user friendly for elderly people.
Methods:
The proposed approach was integrated by a self-designed cuffless, calibration-free, wireless, and wearable PPG-only sensor and a native purposely designed smartphone app using multilayer perceptron machine learning techniques from raw signals. We performed a development and usability study with three older adults (mean age 61.3 years, SD 1.5 years; 66% women) to test the usability and accuracy of the smartphone-based BP monitor.
Results:
The employed artificial neural network model had good average accuracy (>90%) and very strong correlation (>0.90) (P<.001) for predicting the reference BP values of our validation sample (n=150). Bland-Altman plots showed that most of the errors for BP prediction were less than 10 mmHg. However, according to the Association for the Advancement of Medical Instrumentation and British Hypertension Society standards, only diastolic blood pressure prediction met the clinically accepted accuracy thresholds.
Conclusions:
With further development and validation, the proposed system could provide a cost-effective strategy to improve the quality and coverage of health care, particularly in rural zones, areas lacking physicians, and areas with solitary elderly populations.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Errors occurring during blood pressure monitoring
Several factors...
Holter Monitor: 24-Hour Monitoring
Measurement of Blood Pressure

