Related Experiment Video
Updated: Dec 20, 2025

Disposable Dosators for Pulmonary Insufflation of Therapeutic Agents to Small Animals
Published on: March 30, 2017
Use of a closed-system drug transfer device reduces contamination with doxorubicin during bolus injection
Tom Marler-Hausen1, Chris Holt2, Christine Headley3
1Matron, Macmillan Cancer Centre, University College London Hospital.
Background:
Administration of doxorubicin via bolus injection may result in environmental contamination and a risk of nurses becoming exposed. Small spills are frequently observed by nurses when syringes are connected to, and disconnected from, infusion lines.
Aims:
The effect of a closed-system drug transfer device (CSTD) on the release of doxorubicin was studied during administration via bolus injections.
Methods:
10 administrations with the currently used technique and 10 administrations using the CSTD were compared by analysis of doxorubicin contamination on gauze pads, tissues and gloves.
Findings:
Using the current technique, contamination was found during nine administrations, which was mainly on the gauze pads and, to a lesser extent, on the tissues and gloves, indicating release of doxorubicin during administration. With use of the CSTD, contamination was found only on one pair of gloves.
Conclusion:
Use of a CSTD significantly decreased the number of spills and level of contamination compared with the currently used technique and, consequently, the use of such devices offers a safer working environment for nurses.
Related Concept Videos
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Drug Delivery: Parenteral Route
There are three primary parenteral routes: intravenous (IV), intramuscular (IM), and subcutaneous (SC). The IV route introduces the drug directly into the bloodstream, ensuring immediate action. The IM route...
Compartment Models: Single-Compartment Model