Measurement precision at the cut score in medical multiple choice exams: Theory matters
Felicitas-Maria Lahner1,2, Stefan Schauber3, Andrea Carolin Lörwald4
1Institute for Medical Education, University of Bern, Bern, Switzerland. felicitas-maria.lahner@bfh.ch.
Introduction:
In high-stakes assessment, the measurement precision of pass-fail decisions is of great importance. A concept for analyzing the measurement precision at the cut score is conditional reliability, which describes measurement precision for every score achieved in an exam. We compared conditional reliabilities in Classical Test Theory (CTT) and Item Response Theory (IRT) with a special focus on the cut score and potential factors influencing conditional reliability at the cut score.
Methods:
We analyzed 32 multiple-choice exams from three Swiss medical schools comparing conditional reliability at the cut score in IRT and CCT. Additionally, we analyzed potential influencing factors such as the range of examinees' performance, year of study, and number of items using multiple regression.
Results:
In CTT, conditional reliability was highest for very low and very high scores, whereas examinees with medium scores showed low conditional reliabilities. In IRT, the maximum conditional reliability was in the middle of the scale. Therefore, conditional reliability at the cut score was significantly higher in IRT compared with CTT. It was influenced by the range of examinees' performance and number of items. This influence was more pronounced in CTT.
Discussion:
We found that conditional reliability shows inverse distributions and conclusions regarding the measurement precision at the cut score depending on the theory used. As the use of IRT seems to be more appropriate for criterion-oriented standard setting in the framework of competency-based medical education, our findings might have practical implications for the design and quality assurance of medical education assessments.
Related Concept Videos
Accuracy and Precision
Uncertainty in Measurement: Accuracy and Precision
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Accuracy and Errors in Hypothesis Testing
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5%...
Uncertainty in Measurement: Reading Instruments