Related Experiment Video
Updated: Dec 20, 2025

Simulation of Human-induced Vibrations Based on the Characterized In-field Pedestrian Behavior
Published on: April 13, 2016
Optimised Autocalibration Algorithm of Weigh-In-Motion Systems for Direct Mass Enforcement
1Department of Measurement and Electronics, AGH University of Science and Technology, 30-059 Krakow, Poland.
Weigh-In-Motion (WIM) systems suffer from environmental interference, impacting accuracy. An optimized autocalibration algorithm significantly improves WIM precision by reducing sensitivity to these factors, enabling reliable mass enforcement.
Area of Science:
- Engineering
- Metrology
Background:
- Dynamic vehicle weighing systems, Weigh-In-Motion (WIM), are susceptible to environmental factors like weather.
- Sensor sensitivity leads to significant precision loss in WIM measurements over short durations.
- This variability hinders the use of WIM for direct mass enforcement.
Purpose of the Study:
- To address the environmental sensitivity of WIM systems.
- To present an optimized autocalibration algorithm for WIM systems.
- To validate the algorithm's effectiveness through simulations and experimental testing.
Main Methods:
- Development of an optimized autocalibration algorithm for WIM systems.
- Conducting simulation studies to evaluate the algorithm's performance.
- Experimental verification of the algorithm at an in-road WIM site.
Main Results:
- The autocalibration algorithm effectively limits the sensitivity of WIM results to interfering environmental factors.
- Simulation studies confirmed the algorithm's efficacy.
- Experimental results validated the significant improvement in WIM system precision.
Conclusions:
- Autocalibration is a viable solution to enhance the reliability of WIM systems.
- Sufficiently high frequency of reference vehicles is crucial for effective autocalibration.
- The required reference vehicle frequency is dependent on the rate of environmental factor change.
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Mass and Weight
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Conservation of Mass in Moving, Nondeforming Control Volume
In the context of a detention basin, the conservation of mass states that the total mass of water entering the basin must equal the mass leaving the basin plus any accumulation of...
Conservation of Mass in Fixed, Nondeforming Control Volume
In the case of a sewer pipe, which can be modeled...