Optimised Autocalibration Algorithm of Weigh-In-Motion Systems for Direct Mass Enforcement

Piotr Burnos1, Janusz Gajda1

  • 1Department of Measurement and Electronics, AGH University of Science and Technology, 30-059 Krakow, Poland.

Summary

Weigh-In-Motion (WIM) systems suffer from environmental interference, impacting accuracy. An optimized autocalibration algorithm significantly improves WIM precision by reducing sensitivity to these factors, enabling reliable mass enforcement.

Related Concept Videos

Instrument Calibration01:12

Instrument Calibration

Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
604
Mass and Weight01:19

Mass and Weight

Mass and weight are often used interchangeably in everyday conversation. For example,  medical records often show our weight in kilograms, but never in the correct units of newtons. In physics, however, there is an important distinction. Weight is the pull of the Earth on an object. It depends on the distance from the center of the Earth. Weight dramatically varies if we leave the Earth's surface, unlike mass, which does not vary with location. On the Moon, for example, the...
14.7K
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
4.0K
Conservation of Mass in Moving, Nondeforming Control Volume01:14

Conservation of Mass in Moving, Nondeforming Control Volume

Stormwater detention basins are essential in managing runoff during heavy rainfall, particularly in urban areas where impervious surfaces increase the risk of flooding. Understanding the conservation of mass in these systems allows engineers to optimize basin performance, balancing inflow, outflow, and water storage.
In the context of a detention basin, the conservation of mass states that the total mass of water entering the basin must equal the mass leaving the basin plus any accumulation of...
1.2K
Conservation of Mass in Fixed, Nondeforming Control Volume01:07

Conservation of Mass in Fixed, Nondeforming Control Volume

The principle of conservation of mass is fundamental in fluid dynamics and is crucial for analyzing flow within fixed control volumes, such as pipes or ducts. This principle states that the total mass within a control volume remains constant unless altered by the inflow or outflow of mass through the control surfaces. This results in a vital relationship for steady, incompressible flow where the mass entering a system equals the mass leaving it.
In the case of a sewer pipe, which can be modeled...