Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Monomer release from bulk-fill composite resins in different curing protocols
Pinar Gul1, Hamit H Alp2, Mutlu Özcan3
1Department of Restorative Dentistry, Faculty of Dentistry, Atatürk University.
Abstract:
The purpose of this study was to determine the depth of cure and the type and amount of monomers released from bulk-fill composites in different curing protocols. Five different composite resins Filtek Bulk-Fill Posterior, Filtek Bulk-Fill Flowable, SureFil SDR, X-tra Fil, and X-tra base, were used. A light-emitting diode (LED) device was used in 3 different modes (standard, high power, and extra power mode), and a halogen light device was also used as a control. Surface hardness was measured and the depth of cure was calculated. Monomer analysis was performed using high performance liquid chromatography (HPLC). The data were analyzed using Tamhane's T2 post-hoc test (α = 0.05). The cure depth for all materials except for Filtek Bulk-Fill Posterior (extra power mode) and Filtek Bulk-Fill Flowable (high power and extra power modes) was over 80%. Under the conditions of this study, the amount of monomer released from composite resins changed according to the type of composite resin and the light mode used.