All Resting Physiological Indices May Not Be Equivalent - Comparison Between the Diastolic Pressure Ratio and Resting
Masahiro Hoshino1, Taishi Yonetsu2, Tomoyo Sugiyama1
1Department of Cardiology, Tsuchiura Kyodo General Hospital.
Background:
Differences between resting full-cycle ratio (RFR) and diastolic pressure ratio (dPR) have not been sufficiently discussed. This study aimed to investigate if there is a difference in diagnostic performance between RFR and dPR for the functional lesion assessment and to assess if there are specific characteristics for discordant revascularization decision-makings between RFR and dPR.
Methods And Results:
A total of 936 intermediate lesions in 776 patients who underwent measurements of fractional flow reserve (FFR), coronary flow reserve (CFR), and the index of microcirculatory resistance (IMR) were retrospectively studied. Physiological indices were measured from anonymized pressure recordings at an independent core laboratory. Both RFR and dPR measures were highly correlated (r=0.997, P<0.001), with equivalent diagnostic performance relative to FFR-based decision-makings measured by using a dichotomous threshold of 0.80 (accuracy, 79.7% vs. 80.1%, respectively, P=0.960). The rate of diagnostic discordance was 4.7% (44/936), with no RFR-/dPR+ lesions observed. An overall significant difference in FFR and CFR values were detected among RFR/dPR-based classifications. The prevalence of positive studies was significantly higher for RFR than dPR (54.3% vs. 49.6%, respectively, P=0.047) when using the cut-off value of 0.89.
Conclusions:
Both RFR and dPR were highly correlated, but the prevalence of positive studies was significantly different. The revascularization rate may differ significantly according to the resting index used.
More Related Videos
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
08:44Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
Related Concept Videos
Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Physiology of the Heart: The Cardiac Cycle
Diastole: The Relaxation Phase
During diastole, all four heart chambers relax. The atrioventricular (AV) valves open, and the semilunar valves close. This phase sees the lowest chamber pressures, promoting ventricular filling. Venous blood enters the heart through the...
Measurement of Blood Pressure
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...