Related Experiment Video
Updated: Dec 18, 2025

Author Spotlight: Advancing Neonatal Cardiac Diagnostics with Echocardiography-Derived Blood Speckle Imaging
Published on: December 22, 2023
Speckle-Tracking Echocardiography for Cardioncological Evaluation in Bevacizumab-Treated Colorectal Cancer Patients
Andrea Sonaglioni1, Adriana Albini2, Emanuela Fossile3
1Department of Cardiology, Ospedale San Giuseppe IRCCS MultiMedica, Milan, Italy.
Abstract:
Angiogenesis inhibitor Bevacizumab (BVZ) may lead to the development of adverse effects, including hypertension and cardiac ischemia. Whether assessment of changes in myocardial strain by two-dimensional speckle-tracking echocardiography (2D-STE) can be of value in detecting BVZ-mediated cardiotoxicity at an earlier stage is not known. We investigated whether 2D-STE can non-invasively detect early evidence of cardiotoxicity in metastatic colorectal cancer (mCRC) patients treated with BVZ. Between January and June 2019, 25 consecutive patients (71.8 ± 7.5 year/old, 17 males) with mCRC were prospectively enrolled. Patients underwent physical examination, blood tests, and conventional 2D-transthoracic echocardiography implemented with 2D-STE analysis, at baseline and at 3 and 6 months following treatment with BVZ (15 mg/kg every 15 days) + 5-fluorouracil/folinic acid plus oxaliplatin (FOLFOX i.v.). At 6-month follow-up, we assessed occurrence of global longitudinal strain (GLS) impairment (> 15% decrease in GLS compared with baseline) as primary end-point and a new-onset systemic hypertension (secondary end-point). On average, GLS showed a progressive significant impairment after BVZ, from - 17.4 ± 3.2% at baseline to - 16 ± 2.9% (p = 0.003) at 6-month follow-up; > 15% decrease in GLS (primary end-point) was detected in 9 patients (36%). All other strain parameters remained unchanged. New-onset systemic hypertension (secondary end-point) was diagnosed in five patients (20%). No significant changes were observed in serial high-sensitivity cardiac troponin I measurements. No patient developed significant changes in LV size or LV ejection fraction; no case of clinically symptomatic HF was observed during BVZ-treatment. Measurement of GLS by 2D-STE analysis can effectively detect BVZ-mediated cardiotoxicity at an early stage.
More Related Videos
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...