Related Experiment Video
Updated: Dec 18, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Thermal Desorption-Vocus Enables Online Nondestructive Quantification of 2,4,6-Trichloroanisole in Cork Stoppers
Luca Cappellin1,2,3, Felipe D Lopez-Hilfiker3, Veronika Pospisilova3
1Dipartimento di Scienze Chimiche, Università degli Studi di Padova, via Marzolo 1, 35131 Padova, Italy.
Abstract:
2,4,6-Trichloroanisole (TCA) contamination of wine determines huge economic losses for the wine industry estimated to amount to several billion dollars yearly. Over 50 years of studies have determined that this problem is often caused by TCA contamination of the cork stopper, which releases TCA into the wine. The human threshold for TCA is extremely low. A wine contaminated by 1-2 ng/L TCA can be perceived as tainted. Contaminations with <0.5 ng/L TCA are commonly considered negligible and are not perceivable. The possibility of prescreening cork stoppers for TCA contamination would be an enormous advantage. Therefore, the demand for a fast, nondestructive method capable of quantifying the TCA contamination in cork stoppers is impelling. Vastly used analytical methods have so far struggled to provide a fast and reliable solution, whereas sensory analysis by trained panelists is expensive and time-consuming. Here we propose a novel approach based on chemical ionization-time-of-flight (CI-TOF) mass spectrometry employing the "Vocus" ion source and ion-molecule reactor. The technique proved capable of nondestructively quantifying TCA contamination in a single cork stopper in 3 s, with a limit of quantification below the perception threshold. A real test on the industrial scale, quantifying TCA contamination in more than 10000 cork stoppers in a few hours is presented, representing the largest data set of TCA analysis on cork stoppers within the literature and proving the possibility to apply the technique in an industrial environment. The correlation with standard methods for releasable TCA quantification is also discussed.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Related Concept Videos
Volatilization
Mass Spectrometry: Alcohol Fragmentation
Atomic Absorption Spectroscopy: Atomization Methods
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...