Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
[Determination of Cyclohexene in workplace air by Solvent desorption gas chromatography]
Abstract:
Objective: To establish a solvent desorption gas chromatography method for determination of cyclohexene in workplace air. Methods: Cyclohexene in the air of workplace was collected with carbon tube and desorbed by carbon disulfide. The target toxicant was separated with the GC column and analyzed with FID detector, identified by retention time, and quantified by peak area. Results: The linear range of cyclohexene in the air of workplace was 0.77~4 050.00 μg/ml, with a correlation coefficient of 0.9999. The limit of detection was 0.23 μg/ml. The lower limit of quantification was 0.77 μg/ml. The minimum detectable concentration was 0.15 mg/m(3) under1.5 L sampling volume and 1.0 ml extraction solution volume. The within-run precision of different cyclohexene concentrations was 0.62%~1.9% and the between-run precisions was 1.5%~3.5%; The average extraction efficiency was 96.4%; Penetration capacity (100 mg of carbon tube) was 29.4 mg; The average collection efficiency was 100%; The samples could be stored for 7 days at room temperature. When placed in 4 ℃ refrigerator, the samples could be stored for 14 days. The potential coexistence of cyclohexane, hexane, benzene, toluene and ethylbenzene with cyclohexene in the air did not interfere with the results of determination. Conclusion: This method has high sensitivity, precision, accuracy and lower limit of detection and it is applicable for determination of cyclohexene in workplace air.
Related Concept Videos
Mass Spectrometry: Cycloalkane Fragmentation
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Cycloalkene Fragmentation
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....