Amal Mosbahi1, Wael Majdoub1, Badreddine Sriha2
1From the Department of Forensic Medicine, Ibn El Jazzar University Hospital, Kairouan.
The American Journal of Forensic Medicine and Pathology
|June 17, 2020
Abstract:
High-voltage electrocution is mostly unintentional, and it is associated with significant morbidity and mortality due to severe tissue damages. The present report describes an atypical electrocution with multiple victims and a fatal outcome of a 48-year-old man due to unusual neck injuries caused by accidental electrical burns.
Related Concept Videos
Burn Injuries
3.8K
Burn injuries occur when the skin and underlying tissues are damaged due to exposure to heat, electricity, chemicals, radiation, or friction. They can vary in severity, from minor superficial burns to severe deep burns that can be life-threatening.
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...
3.8K
Esophageal Perforation-I: Introduction
311
Esophageal perforation is a severe medical condition characterized by a breach in the integrity of the esophageal wall. This breach can occur due to various factors such as trauma, medical procedures, or underlying diseases. When the esophageal wall is compromised, it allows food, fluids, and digestive juices into the chest cavity or adjacent structures, leading to potential complications and health risks.
The location of esophageal perforation can vary, occurring anywhere along the esophagus....
The location of esophageal perforation can vary, occurring anywhere along the esophagus....
311
Household Wiring And Electrical Safety
1.5K
Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always...
1.5K