Related Experiment Video
Updated: Dec 17, 2025

Proton Transfer and Protein Conformation Dynamics in Photosensitive Proteins by Time-resolved Step-scan Fourier-transform Infrared Spectroscopy
Published on: June 27, 2014
The Next Generation of IR Spectroscopy: EC-QCL-Based Mid-IR Transmission Spectroscopy of Proteins with Balanced
Christopher K Akhgar1, Georg Ramer1, Mateusz Żbik2
1Institute of Chemical Technologies and Analytics, Technische Universität Wien, Getreidemarkt 9, 1060 Vienna, Austria.
Abstract:
We report a mid-IR transmission setup for the analysis of the protein amide I and amide II band in aqueous solutions that achieves a limit of detection as low as 0.0025 mg mL-1 (outperforming our previous results and other state-of-the-art mid-IR-based techniques by almost an order of magnitude). This large improvement is made possible by combining the latest-generation external cavity-quantum cascade laser (EC-QCL) operated at room temperature with an optimized double-beam optical setup that adjusts the path length (26 μm) to ensure robust sample handling. For minimizing the noise introduced by the high-intensity laser light source, a thermoelectrically cooled mercury cadmium telluride balanced detection module was employed. In this way, noise levels better by a factor of up to 20 were achieved compared with single-channel measurements. Characteristic spectral features of proteins with different secondary structures were successfully identified at concentrations as low as 0.1 mg mL-1. Furthermore, a highly linear response was demonstrated for concentrations between 0.05 and 10 mg mL-1. The total acquisition time of the setup can be adapted to fulfill the required sensitivity of the protein measurements and to ensure maximum flexibility for future applications. The presented setup combines high sensitivity, large optical path lengths, and short measurement times and thus outperforms previous research type EC-QCL setups as well as commercially available instruments. This opens a wide range of future applications including protein-ligand interaction studies as well as qualitative and quantitative analyses of proteins in complex matrices such as those found in up- and downstream bioprocess monitoring and similar challenging applications which can not be readily met by conventional FT-IR spectroscopy.
Related Concept Videos
IR Spectrometers
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Molecular Spectroscopy: Absorption and Emission
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent of conjugation in...
Applications of IR Spectroscopy: Overview

