Purpose:
To objectively compare structured and freeform abdominopelvic CT reports based on the number and types of errors as well as report length.
Methods:
90 structured and 89 freeform reports from abdominopelvic CT scans with IV contrast obtained for the indication of abdominal pain were randomly selected for review. Each report was reviewed for errors, which were counted and categorized based on the type of error. The total number of words in each report was tallied.
Results:
105 total errors were found in the structured reports, compared to 157 total errors in freeform reports. There were 1.16 errors per structured report and 1.76 errors per freeform report (p < 0.001). 48% of structured reports contained at least one error, while 71% of freeform reports contained at least one error (p = 0.002). When a difference existed between the styles with regard to error categories, more errors were observed in freeform reports, with the exception of the duplicated period error where structured reports had more errors. No difference on the basis of average words per report existed, with 219.2 words per report for each reporting style.
Conclusion:
The use of structured reporting for abdominopelvic CT results in less errors in the report when compared to freeform reporting, potentially reducing clinically significant adverse outcomes in patient care. The report length on the basis of number of words per report is not different between the two reporting styles.
More Related Videos
09:02Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies VI: Voiding Cystourethrography and Cystography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...