Related Experiment Video
Updated: Dec 13, 2025

A Postoperative Evaluation Guideline for Computer-Assisted Reconstruction of the Mandible
Published on: January 28, 2020
Platform switching in two-implant bar-retained mandibular overdentures: 1-year results from a split-mouth randomized
Samir Abou-Ayash1, Martin Schimmel1,2, Dominik Kraus3
1Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland.
Objectives:
The concept of platform switching is widely applied in current implant dentistry; however, the influence on peri-implant bone-level alterations (ΔIBL), especially in the field of implant overdentures (IODs), remains inconclusive. Therefore, the present study aimed to test the alternative hypothesis that there is an equivalent ΔIBLs at platform-switching and platform-matching implant abutments in 2-implant bar-retained IODs.
Materials And Methods:
Two interforaminal implants were placed in 32 subjects, who were randomly assigned to either an immediate- or a 3-month post-placement loading group. Furthermore, one implant in each subject was randomly assigned to receive a platform-switched abutment (test), and one a platform-matching abutment (control). The implants were splinted with prefabricated, chairside customized bars. ΔIBL was recorded by using customized radiograph holders at implant placement, implant loading, 3 months, 6 months, and 12 months after loading.
Results:
After 1 year, equivalent ΔIBL could be identified (test: -0.51 mm ± 0.49 versus control: -0.56 mm ± 0.52; p < .001). ΔIBL increased over time and was more pronounced in the delayed-loaded implants (-0.87 mm ± 0.61) relative to the immediately loaded implants (-0.35 mm ± 0.43; p = .022).
Conclusions:
The prosthetic concept of platform switching does not necessarily lead to reduced bone loss. Immediate-loading of implants, primarily splinted with a bar, might be beneficial regarding peri-implant bone-level alterations over a short-term period.
More Related Videos
07:32Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment
Published on: February 23, 2024
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla