Related Experiment Video
Updated: Dec 13, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
[Determination of trichlorobenzene in workplace air by solvent desorption gas chromatography]
1Shenzhen Longhua District Centers for Disease Control and Prevention, Shenzhen 518109, China.
Abstract:
Objective: To develop a solvent desorption-gas chromatography method for determination of trichlorobenzene in workplace air. Methods: Trichlorobenzene in workplace air were captured by Sampling tube consisting of glass fiber filter and solvent desorption activated carbon and desorbed with carbon disulfide, separated through capillary chromatographic column, and then analyzed by gas chromatography-electron capture detector. Results: The linear ranges of 1, 2, 3-trichlorobenzene, 1, 2, 4-trichlorobenzene and 1, 3, 5-trichlorobenzene were 12.20-1220.00, 16.60-1660.00 and 14.80-1480.00 μg/L, respectively, and the related coefficients were between 0.99946 to 0.99948. The relative standard deviations (RSD) within the groups of 1, 2, 3-trichlorobenzene, 1, 2, 4-trichlorobenzene and 1, 3, 5-trichlorobenzene were 1.96%-2.68%, 1.73%-2.82% and 1.81%-2.56%, respectively, and the RSD between the groups were 3.27%-4.25%, 2.85%-4.83% and 3.46%-4.43%, respectively. The average recovery efficiencies were 92.4%, 92.0% and 93.6%, respectively. The minimum quantification concentrations were 0.81, 1.53 and 1.18 μg/m(3), respectively (3 ml desorption solution, 15.00 L sample) . The samples could be stored at room temperature for at least 5 days. Conclusion: This method could be used for monitoring of 1, 2, 3-trichlorobenzene, 1, 2, 4-trichlorobenzene and 1, 3, 5-trichlorobenzene in workplace air.
More Related Videos
12:24Laboratory Estimation of Net Trophic Transfer Efficiencies of PCB Congeners to Lake Trout Salvelinus namaycush from Its Prey
Published on: August 29, 2014
07:32Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...