Integrated Compensatory Responses in a Human Model of Hemorrhage
Published on: November 20, 2016
Harnessing the Manifold Structure of Cardiomechanical Signals for Physiological Monitoring During Hemorrhage
Objective:
Local oscillation of the chest wall in response to events during the cardiac cycle may be captured using a sensing modality called seismocardiography (SCG), which is commonly used to infer cardiac time intervals (CTIs) such as the pre-ejection period (PEP). An important factor impeding the ubiquitous application of SCG for cardiac monitoring is that morphological variability of the signals makes consistent inference of CTIs a difficult task in the time-domain. The goal of this work is therefore to enable SCG-based physiological monitoring during trauma-induced hemorrhage using signal dynamics rather than morphological features.
Methods:
We introduce and explore the observation that SCG signals follow a consistent low-dimensional manifold structure during periods of changing PEP induced in a porcine model of trauma injury. Furthermore, we show that the distance traveled along this manifold correlates strongly to changes in PEP ( ∆PEP).
Results:
∆PEP estimation during hemorrhage was achieved with a median R2 of 92.5% using a rapid manifold approximation method, comparable to an ISOMAP reference standard, which achieved an R2 of 95.3%.
Conclusion:
Rapidly approximating the manifold structure of SCG signals allows for physiological inference abstracted from the time-domain, laying the groundwork for robust, morphology-independent processing methods.
Significance:
Ultimately, this work represents an important advancement in SCG processing, enabling future clinical tools for trauma injury management.
More Related Videos
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
07:51Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...