Evaluation of the metrological reliability of a graduated cylinder from experimental data from an in-situ calibration
Related Experiment Video
Updated: Dec 11, 2025

Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
José Daniel Hernández-Vásquez1, Cristian Antonio Pedraza-Yepes2, Andrés David Rodriguez-Salas3
1Universidad Antonio Nariño, Faculty of Mechanical, Electronic and Biomedical Engineering (FIMEB), Research Group GIFOURIER. Mechanical Engineering Program, Puerto Colombia, Colombia.
Abstract:
This work presents the data experimentally collected in a chemical laboratory for the calibration of a graduated cylinder. There are several factors that can influence the volume measurement using this type of instrument and, consequently, its metrological reliability, for example: the internal geometry, the environmental conditions (ambient temperature, atmospheric pressure and relative humidity), the acceleration of gravity, the density of the air, among others. For the data collection it was necessary to use a glass liquid thermometer (Range: 0-10 °C), a digital thermohygrometer (Range: 0-100 °C and 0-99%RH) and a digital barometer (Range: 0-9999 mbar). Additionally, an analytical scale (Range: 0-220 g) was used for mass measurement. From the measurements obtained, it was possible to determine the in-situ air density and the buoyancy factor that influences the mass measurement. The data, rigorously obtained, present a potential use to determine the metrological reliability of a graduated cylinder for laboratory use and, additionally, contribute to perform a metrological validation of alternative methods for the calibration of graduated cylinder.
More Related Videos
10:24Applicability Analysis of Assessment Methods for Morphological Parameters of Corroded Steel Bars
Published on: November 1, 2018
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Uncertainty in Measurement: Reading Instruments
Uncertainty in Measurement: Accuracy and Precision
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Random and Systematic Errors