Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Spontaneous cortical vasodynamics form a multiscale propagation architecture in the awake brain.

bioRxiv : the preprint server for biology·2026
Same author

Vessel-Resolved Mapping of Perivascular Spaces Reveals Hierarchical Neurofluid Organization <i>In Vivo</i>.

bioRxiv : the preprint server for biology·2026
Same author

Smooth Muscle Dysfunction Drives Cerebrovascular Reserve Failure and End-Organ Brain Injury.

bioRxiv : the preprint server for biology·2026
Same author

MoCo + ROVir: Synergy Between Respiratory Motion Compensation and Cardiac Receive Region Focusing for Cardiac MRI.

Magnetic resonance in medicine·2026
Same author

T<sub>1</sub>-weighted fMRI in mouse visual cortex using an iron oxide nanoparticle contrast agent and UTE imaging at 9.4 T.

Magnetic resonance in medicine·2025
Same author

Multiparametric Dynamic Contrast Imaging for Voxelwise Quantitative Assessment of Brain Tumors.

Radiology. Imaging cancer·2025
Same journal

Susceptibility Source Separation Unveils Paramagnetic and Diamagnetic Trajectories in Healthy Brains From 5 to 90 Years.

NMR in biomedicine·2026
Same journal

Skeletal Motor Unit Recruitment During Periodic Auditory Cueing: A Simultaneous Behavioral and Motor Unit Magnetic Resonance Imaging (MUMRI) Study.

NMR in biomedicine·2026
Same journal

Quantitative Guanidinium CEST-Based pH Mapping at 3 T in Healthy and Pathological Muscle.

NMR in biomedicine·2026
Same journal

Liver Diffusion Weighted MRI: Effect of Iron Overload on Apparent Diffusion Coefficient.

NMR in biomedicine·2026
Same journal

In Vivo Assessment of Placental Structure and Perfusion in Late-Gestation Pregnancies and Their Association With Fetal Growth.

NMR in biomedicine·2026
Same journal

Reproducibility of Splanchnic Blood Flow Measured Using Phase-Contrast MRI.

NMR in biomedicine·2026
See all related articles

Related Experiment Video

Updated: Dec 11, 2025

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
17:16

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring

Published on: December 9, 2010

10.6K

Optimizing diffusion MRI acquisition efficiency of rodent brain using simultaneous multislice EPI.

Hsu-Lei Lee1,2, Xiaoqing Alice Zhou1, Zengmin Li1

  • 1Queensland Brain Institute, The University of Queensland, Brisbane, Australia.

NMR in Biomedicine
|August 26, 2020
PubMed
Summary
This summary is machine-generated.

This study introduces a new method to speed up brain scans in mice using a technique called multiband imaging. By capturing multiple slices of the brain at once, researchers can collect high-quality data much faster than traditional methods. This approach works well even on standard scanners that lack specialized hardware. The results show clearer images and more reliable measurements of brain structure, which helps scientists better map brain connections.

Keywords:
DTIdiffusion weighted MRImulti-bandoptimizationsimultaneous multi-slicepreclinical MRIHadamard encodingconnectome mappingsignal-to-noise ratiowhite matter integrity

Frequently Asked Questions

More Related Videos

Simultaneous PET/MRI Imaging During Mouse Cerebral Hypoxia-ischemia
10:35

Simultaneous PET/MRI Imaging During Mouse Cerebral Hypoxia-ischemia

Published on: September 20, 2015

12.6K
Diffusion Imaging in the Rat Cervical Spinal Cord
10:46

Diffusion Imaging in the Rat Cervical Spinal Cord

Published on: April 7, 2015

12.0K

Related Experiment Videos

Last Updated: Dec 11, 2025

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
17:16

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring

Published on: December 9, 2010

10.6K
Simultaneous PET/MRI Imaging During Mouse Cerebral Hypoxia-ischemia
10:35

Simultaneous PET/MRI Imaging During Mouse Cerebral Hypoxia-ischemia

Published on: September 20, 2015

12.6K
Diffusion Imaging in the Rat Cervical Spinal Cord
10:46

Diffusion Imaging in the Rat Cervical Spinal Cord

Published on: April 7, 2015

12.0K

Area of Science:

  • Neuroimaging research within diffusion MRI methodology
  • Preclinical imaging techniques involving simultaneous multislice acquisition

Background:

Long scan durations represent a significant barrier for high-resolution brain imaging in small animal models. Researchers often struggle to balance spatial detail with the need for rapid data collection. Prior work has shown that traditional scanning techniques frequently result in suboptimal signal quality. That uncertainty drove the development of parallel imaging strategies to improve efficiency. However, these methods often rely on specialized hardware that remains inaccessible for many laboratories. No prior work had resolved the challenge of implementing these advanced protocols without high-density radiofrequency coil arrays. This gap motivated the exploration of alternative encoding schemes for preclinical systems. The current investigation addresses these limitations by leveraging multiband excitation to enhance acquisition throughput.

Purpose Of The Study:

This study aims to optimize the acquisition efficiency of rodent brain imaging using a simultaneous multislice approach. Researchers sought to overcome the long scan times typically required for high-resolution diffusion tensor imaging. The project addresses the lack of practical multiband solutions for scanners with limited radiofrequency coil channels. Investigators hypothesized that Hadamard-encoded pulses could enable faster data collection without sacrificing image quality. The motivation stems from the need to perform high-resolution connectome studies in small animal models. By reducing repetition time, the team intended to maximize signal-to-noise efficiency across the entire brain volume. This work explores whether such advancements can be achieved without relying on high-density coil arrays. The primary goal remains the development of a robust, accessible protocol for preclinical neuroimaging.

Main Methods:

Review approach involves implementing a multiband excitation sequence on a 9.4 Tesla preclinical scanner. The team utilized Hadamard-encoded pulses to excite four distinct brain planes concurrently. This design avoids the necessity for high-density radiofrequency coil arrays typically required for parallel imaging. Researchers developed a self-calibrated phase decoding algorithm to correct for shot-to-shot signal fluctuations. The protocol achieved whole-brain coverage with 0.2 mm isotropic resolution. Data collection compared this new multiband strategy against standard single-band acquisition parameters. Both techniques maintained identical total scan durations to ensure a fair performance assessment. Analysis focused on quantifying signal-to-noise improvements and structural metric stability across the white matter.

Main Results:

Key findings from the literature demonstrate that multiband acquisition increases signal-to-noise ratio by 40% in white matter compared to single-band methods. This gain in signal quality directly translates to more reliable measurements of fractional anisotropy and mean diffusivity. The researchers observed that eigenvector orientation estimates became significantly more stable across the brain volume. Attenuation of cerebrospinal fluid signals effectively minimized free-water contamination in the final images. The protocol successfully captured 84 slices with 0.2 mm isotropic resolution during a single session. These results confirm that the Hadamard-encoded approach overcomes previous limitations regarding repetition time reduction. The data suggests that high-resolution whole-brain imaging is feasible without specialized parallel hardware. All reported improvements remained consistent across the entire 9.4 Tesla scanning environment.

Conclusions:

The authors propose that multiband encoding significantly improves the efficiency of preclinical brain mapping protocols. This approach allows for high-resolution data collection without requiring complex hardware upgrades. Researchers suggest that the observed signal gains lead to more stable estimates of structural connectivity metrics. The team notes that reduced free-water contamination enhances the precision of white matter analysis. Synthesis and implications indicate that this method facilitates larger-scale connectome studies in rodent models. The findings demonstrate that Hadamard-encoded pulses effectively manage phase variations during simultaneous slice acquisition. This work confirms that high-quality imaging is achievable on standard preclinical scanners. The study provides a practical framework for optimizing scan parameters in future neuroscientific research.

The researchers propose that Hadamard-encoded pulses allow for simultaneous excitation of four slices. This mechanism reduces repetition time, thereby increasing signal efficiency by 40% compared to single-band methods. The approach specifically addresses phase variations through a self-calibrated decoding process.

The study utilizes Hadamard-encoding, a mathematical approach to separate signals from multiple slices. Unlike parallel imaging, this method does not require high-density radiofrequency coil arrays. It relies on specific pulse sequences to achieve high-resolution coverage at 9.4 Tesla.

A 9.4 Tesla field strength is necessary to maintain sufficient signal quality during high-resolution scans. While lower fields might struggle with the signal loss associated with thinner slices, this specific intensity supports the 0.2 mm isotropic resolution achieved by the authors.

The authors use self-calibrated phase decoding to manage shot-to-shot variations. This data processing step is vital for reconstructing images from the multiband pulses. It ensures that the combined signals remain accurate despite the rapid acquisition speed.

The researchers measured fractional anisotropy, mean diffusivity, and eigenvector orientation. These metrics showed reduced variability when using the multiband approach. The team also observed that cerebrospinal fluid signals were successfully attenuated during the scanning process.

The authors claim this method enables highly efficient preclinical diffusion tensor imaging. They suggest it will facilitate future connectome studies by allowing for faster, high-resolution whole-brain coverage. This advancement removes the hardware constraints that previously limited such research.