[Study on normal reference range of smooth tracking gain for healthy young people]
Chao Wen1, Taisheng Chen2, Qiaomei Deng2
1The First Center Clinical College of Tianjin Medical University,Tianjin,300192,China.
Abstract:
Objective:Analysis of normal reference value of smooth pursuit test for normal young people. Method:Thirty normal young volunteers were tested by Synapsys videonystagmography. The maximum horizontal tracking angle was 30 °, the vertical maximum tracking angle was 20°, and the frequency was 0.30 Hz, 0.45 Hz and 0.60 Hz, respectively, and the gain under different conditions is used as the observation index. Result:When the frequency is 0.3 Hz, 0.45 Hz, 0.60 Hz, the left and right horizontal gain is 0.92±0.07/0.93±0.07, 0.87±0.08/0.88±0.11, 0.79±0.11/0.78±0.13, respectively, and the asymmetry of left/right gain is 0.021±0.017, 0.031±0.026, 0.037±0.040; the up and down vertical gain is 0.82±0.16/0.80±0.16, 0.78±0.17/0.72±0.15, 0.68±0.20/0.61±0.15, and the asymmetry of the upper/lower gain is 0.046±0.045, 0.069±0.058, 0.109±0.076. Comparing and analyzing the paired left and right gain values of the three frequencies by paired t test, the differences were not statistically significant (P>0.05). Paired t -test of gain value for different frequency of up and down stationary tracking, the difference was not statistically significant at 0.30 Hz(P>0.05), but the gain at 0.45 Hz and 0.60 Hz has significant difference(P<0.05). Comparing the gains of different frequencies in the same direction, the differences in analysis of variance were statistically significant(P<0.05). Conclusion:The gain value of smooth pursuit test for normal young people can be affected by tracking frequency and direction. At the same frequency, the left/right tracking of 3 frequencies and the up/down tracking gain values of 0.30 Hz are symmetrical, but at 0.45 Hz and 0.6 Hz, the up tracking gain is greater than the down tracking gain, and the gain value in the same direction gradually decreases with the increase of frequency, is the clinical smooth pursuit test is mainly based on 0.30 Hz.
More Related Videos
10:12Three Dimensional Vestibular Ocular Reflex Testing Using a Six Degrees of Freedom Motion Platform
Published on: May 23, 2013
07:24Using Eye-tracking to Assess the Relative Importance of Visual and Vestibular Input to Subcortical Motion Processing in the Roll Plane
Published on: August 22, 2025
Related Concept Videos
Regression Toward the Mean
Smooth Muscle Contraction
The onset of contraction is triggered by an increase in calcium ions within the sarcoplasm, similar to the process in striated muscle. However, smooth muscles have a relatively smaller reservoir of the sarcoplasmic...
Serum Studies: Renal Function Tests
Root Mean Square
For example, consider the velocity of gas molecules in a container. The gas molecules are moving in different directions, which might impart positive and negative...