Related Experiment Video
Updated: Dec 10, 2025

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Batch Reading and Interrupted Interpretation of Digital Screening Mammograms Without and With Tomosynthesis
Ethan O Cohen1, Michele Lesslie2, Olena Weaver3
1Faculty Lead of Marketing, Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas.
Objective:
To compare batch reading and interrupted interpretation for modern screening mammography.
Methods:
We retrospectively reviewed digital mammograms without and with tomosynthesis that were originally interpreted with batch reading or interrupted interpretation between January 2015 and June 2017. The following performance metrics were compared: recall rate (per 100 examinations), cancer detection rate (per 1,000 examinations), and positive predictive values for recall and biopsy.
Results:
In all, 9,832 digital mammograms were batch read, yielding a recall rate of 9.98%, cancer detection rate of 4.27, and positive predictive values for recall and biopsy of 4.40% and 35.5%, respectively. There were 49,496 digital mammograms that were read with interrupted interpretation, yielding a recall rate of 11.3%, cancer detection rate of 4.44, and positive predictive values for recall and biopsy of 3.92% and 30.1%, respectively. Of the digital mammograms with tomosynthesis, 7,075 were batch read, yielding a recall rate of 6.98%, cancer detection rate of 5.37, and positive predictive values for recall and biopsy of 7.69% and 38.0%, respectively. Of the digital mammograms with tomosynthesis, 24,380 were read with interrupted interpretation, yielding a recall rate of 8.30%, cancer detection rate of 5.41, and positive predictive values for recall and biopsy of 6.52% and 33.3%, respectively. For both digital mammograms without and with tomosynthesis, recall rates improved with batch reading compared with interrupted interpretation (P < .001), but no significant differences were seen for other metrics.
Discussion:
Batch reading digital mammograms without and with tomosynthesis improves recall rates while maintaining cancer detection rates and positive predictive values compared with interrupted interpretation.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...

