Related Experiment Video
Updated: Dec 7, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
The three-point bending test of fiber-reinforced composite root canal posts
Michał Biały1, Agnieszka Szust2, Piotr Napadłek1
1Department of Dental Prosthetics, Wroclaw Medical University, Poland.
Background:
The primary reason for using a post is to retain the core with the objective to restore the missing coronal tooth structure. To achieve optimum results, the materials that are used to restore endodontically treated teeth should have physical and mechanical properties that are similar to that of dentin.
Objectives:
To characterize the strength parameters of fiber-reinforced composite (FRC) posts with the application of a three-point test. The mean fracture load, flexural strength and flexural modulus were taken into consideration.
Material And Methods:
For the three-point strength tests, 5 kinds of fiberglass root-posts were used: GC Fiber Post (GC America, Alsip, USA), Mirafit White (Hager Werken, Duisburg, Germany), Innopost (InnoTech, Verona, Italy), Rebilda Post (Voco, Cuxhaven, Germany), and EverStick Post (GC Europe, Leuven, Belgium). For each system, 15 FRC posts were tested. All posts had the same diameter, length and shape. The three-point test was carried out in accordance with ISO 10477:2004, using the Instron-5944 testing machine (Instron, Norwood, USA). The test was carried out until the sample was broken.
Results:
The highest force values (67.6 N) were recorded for the GC posts, and the lowest force required to break the sample (29.6 N) was noted for the EverStick Posts. In the case of bending strength, the highest values were also recorded for GC posts (912.4 MPa). Low bending strengths were obtained for the Mirafit White posts (537.2 MPa); however, the EverStick Posts were the weakest (436.2 MPa). Rebilda posts showed the highest modulus of elasticity - 31.1 GPa. The lowest values of the elastic modulus were registered for EverStick Posts - 12.5 GPa.
Conclusions:
There were statistically significant differences in fracture loads, flexural strengths and flexural modulus of the FRC-post systems tested. Individually polymerized FRC material showed lower flexural properties than compared prefabricated FRC posts.
More Related Videos
Related Concept Videos
Bending
In pure bending, the bending stress in a beam is calculated based on the bending moment and...
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Residual Stresses in Bending
Bending of Material: Problem Solving
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Members Made of Elastoplastic Material
As the bending moment...