Comparison Between Closed-Loop Insulin Delivery System (the Artificial Pancreas) and Sensor-Augmented Pump Therapy: A

Ahmad Haidar1,2, Laurent Legault3,4, Marie Raffray5

  • 1Department of Biomedical Engineering, McGill University, Montreal, Canada.

Summary

Closed-loop automated insulin delivery, or artificial pancreas, significantly improves glucose control in type 1 diabetes patients compared to traditional pump therapy. This advanced system enhances time in target glucose ranges and reduces hypoglycemia.

Related Concept Videos

Insulin: Dosing Regimen and Adverse Effects01:16

Insulin: Dosing Regimen and Adverse Effects

Insulin-replacement therapy usually includes both long-acting insulin (basal) and short-acting insulin (to cater to postprandial needs). In a diverse group of type 1 diabetes patients, the average daily insulin dose is typically 0.5-0.7 units/kg body weight. However, obese patients and pubertal adolescents may need more due to insulin resistance.
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
519
Crossover Experiments01:16

Crossover Experiments

Crossover experiments, also called the repeated-measurements design, is a study design in which all experimental units are exposed to all treatments in different periods. Crossover experiments are generally used in psychology, the pharmaceutical industry, agriculture, and medicine.
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
4.4K
Insulin Formulations: Types and Delivery01:27

Insulin Formulations: Types and Delivery

Insulin preparations are categorized by their duration of action into short-acting and long-acting types. Two strategies are used to modify insulin's absorption and pharmacokinetic profile: slowing the absorption post-subcutaneous injection, or altering human insulin's amino acid sequence or protein structure. These changes retain the insulin's ability to bind to the insulin receptor, but alter its behavior in solution or after injection.
Short-acting insulins are divided into...
526
Open and closed-loop control systems01:17

Open and closed-loop control systems

Control systems are foundational elements in automation and engineering. They are broadly categorized into open-loop and closed-loop systems. These classifications hinge on the presence or absence of feedback mechanisms, significantly influencing the system's performance, complexity, and application.
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
1.4K
Insulin: The Receptor and Signaling Pathways01:28

Insulin: The Receptor and Signaling Pathways

Insulin action is mediated through a receptor tyrosine kinase, akin to the IGF-1 receptor. The number of receptors per cell varies significantly, from 40 on erythrocytes to 300,000 on adipocytes and hepatocytes. The insulin receptor consists of linked α/β subunit dimers, forming a heterotetramer glycoprotein with two extracellular α subunits and two β subunits spanning the membrane. The α subunits inhibit the inherent tyrosine kinase activity of the β subunits, but...
2.2K