Related Experiment Video
Updated: Dec 6, 2025

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Fluoroless and contrast-free catheter ablation without a lead apron in routine clinical practice
Takumi J Matsubara1,2, Katsuhito Fujiu3,4, Yu Shimizu5
1Department of Cardiovascular Medicine, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo, 113-8655, Japan. matsubarat-int@h.u-tokyo.ac.jp.
Abstract:
The technique of catheter ablation has been improved within the past few decades, especially by three-dimensional (3D) mapping system. 3D mapping system has reduced radiation exposure but ablation procedures still require fluoroscopy. Our previous study showed the safety and efficacy of catheter ablation based on intracardiac echogram combined with CARTOSOUND/CARTO3 system, however fluoroscopy use for an average of 16 min is required for this procedure. The present study was aimed to reduce radiation exposure to zero and establish a radiation free catheter ablation method with the goal of utilizing it in routine clinical practice. We conducted single center, retrospective study during 2019 April to 2020 February. Consecutive 76 patients were enrolled. In the first 18 cases, the previously reported procedure (CARTOSOUND/CARTO3 method) was used. The remaining 58 cases were transitioned to fluoroless catheter ablation. The procedure time, success rates and complication rates were analyzed. Not only AF patients but atrial flutter (AFL), paroxysmal supraventricular tachycardia (PSVT) and ventricular arrhythmia patients were included. Catheter positioning, catheter visualization and collecting the geometry of each camber of the heart were conducted by using contact force and ICE based geometry on CARTO system without either prior computed tomography (CT) or magnetic resonance image (MRI). In fluoroless group, all catheter ablations were successfully performed without lead aprons. No complications occurred in either group. There were no significant differences in procedure time in any type of procedure (Total procedure time Fluoro-group; 149 ± 51 min vs. Fluoroless-group; 162 ± 43 min, N.S.), (PSVT 170 ± 53 min vs. 162 ± 29 min, N.S.), (AFL 110 ± 70 min vs. 123 ± 43 min, N.S.), (AF 162 ± 43 min vs. 163 ± 32 min, N.S.). The total radiation time was reduced to zero in fluoroless group. Catheter ablation with ICE and 3D mapping system guide without fluoroscopy could be safely performed with a high success rate, without any prior CT/MRI 3D images. Radiation was reduced completely for patients and staff, negating the need for protective wear for operators.
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization IV: Nursing Management