Related Experiment Video
Updated: Jan 17, 2026

In Silico Clinical Trials for Cardiovascular Disease
Published on: May 27, 2022
Multi-scale heart simulation augments the explainability of artificial intelligence-enabled electrocardiogram through
Jun-Ichi Okada1, Katsuhito Fujiu1, Eriko Hasumi1
1Department of Advanced Cardiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8654, Japan.
Background And Objectives:
Although artificial-intelligence-enhanced electrocardiograms (AI-ECGs) offer prediction and diagnosis capabilities superior to those of humans, they exhibit poor explainability and interpretability because of their complex-neural-network-derived black-box characteristics. To augment the explainability of artificial intelligence-enhanced electrocardiogram (AI-ECG) analysis, we proposed a method combining AI-ECG and synthetic ECG database created by a multi-scale heart simulator.
Methods:
Using the "UT-Heart" multi-scale heart simulator running on the supercomputer Fugaku, we simulated 30,720 12-lead ECG recordings. This dataset comprises an exhaustive combination of 12 cellular and subcellular pathologies reportedly associated with heart failure and was analysed using a previously developed AI-ECG system that accurately classifies ECGs into New York Heart Association (NYHA) functional classes. By analysing the relationship between HF severity and labelled pathology in each simulated ECG recording, we elucidated the origin of abnormalities detected using AI-ECG.
Results:
AI-ECG classified 30,618 ECGs (excluding 102 arrhythmia cases) into 2234 control and 28,384 HF cases. A separate three-group classification identified 2234 control, 18,444 NYHA I/II, and 9940 NYHA III/IV cases. In the two-group classification, significant differences (p < 0.01) were observed in sodium (Na) and Na-calcium exchanger currents and the transmural distribution of distinct cell types. Although the three-group classification revealed a severity-dependent progression of the Na current abnormality, the cell distribution in NYHA III/IV was closer to that of normal cases than to that of NYHA I/II. These findings did not explain the changes in the ECG waveform that the AI-ECG identified as notable features of heart failure in the heatmap analysis.
Conclusions:
The ECG dataset generated using the multi-scale heart simulator can enhance the explainability of AI-ECGs by elucidating the mechanisms underlying HF-severity-specific changes in ECGs of heart failure.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...