Background:
Left bundle branch area pacing (LBBAP) is an innovative pacing technology, which needs further study.
Methods:
Seventy LBBAP patients with intrinsic QRS duration (QRSd) less than 120 ms were consecutively enrolled in our center. According to whether the left bundle branch potential (LBBp) was recorded or not, the patients were divided into the potential positive group (LBBAP+) and the potential negative group (LBBAP-). Electrocardiographic and echocardiographic parameters were used to evaluate electrical and mechanical characteristics. Lead parameters and complications were followed-up.
Results:
There were 52 patients in LBBAP+ and 18 patients in LBBAP-. The QRSd and the left ventricular activation time (LVAT) were wider after LBBAP. QRSd showed no significant difference between LBBAP+ and LBBAP-. LVAT was significantly shorter in LBBAP+ than in LBBAP-. Frontal QRS axis shifted leftward and the V1 morphologies changed after LBBAP. QRS axis and V1 morphologies showed no significant differences between two groups. Paced R-wave transition moved forward compared with intrinsic R-wave transition in both groups. Peak systolic strain of left ventricle (LVPSS) increased, and peak systolic dispersion of left ventricle (LVPSD) did not change significantly after LBBAP. Systolic and diastolic function as well as mechanical synchronism had no significant differences between two groups. LBBAP had great pacing parameters.
Conclusion:
LBBAP changes electrical and mechanical characteristics and has good safety in patients with normal intrinsic QRSd. LBBAP+ and LBBAP- show no significant differences in mechanical synchronization and interventricular electrical synchronization. The LBBAP+ shows better left ventricular electrical synchronicity.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
09:23Confirmation of Myocardial Ischemia and Reperfusion Injury in Mice Using Surface Pad Electrocardiography
Published on: November 24, 2016
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Electrophysiology of Normal Cardiac Rhythm
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...