Fluorescence lifetime probes for detection of RNA degradation
Riku Hirata1, Kazutaka Hirakawa, Naotaka Shimada
1Department of Interdisciplinary Science and Engineering in Health Systems, Okayama University, Okayama, Japan. ohtsuk@okayama-u.ac.jp.
Abstract:
To investigate RNA degradation in live cells, detection methods that do not require RNA extraction from cells are necessary. In this study, we examined the utility of fluorescence lifetime measurements using a probe attached to the end of an RNA molecule for detecting RNA degradation. We optimized a short fluorescein-labeled RNA sequence whose fluorescence lifetime varied significantly before and after degradation. The selected HHG-fluorescein sequence (H = U, C, or A) is a promising RNA labeling unit (fluorescence lifetime probe) for live cell imaging of RNA degradation.
More Related Videos
12:20Real-time Imaging of Single Engineered RNA Transcripts in Living Cells Using Ratiometric Bimolecular Beacons
Published on: August 6, 2014
12:06Single-Cell Quantification of Protein Degradation Rates by Time-Lapse Fluorescence Microscopy in Adherent Cell Culture
Published on: February 4, 2018
Related Concept Videos
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Real Time RT-PCR
The real-time quantification of the number of amplified products is...