Related Experiment Video
Updated: Dec 2, 2025

A TIRF Microscopy Technique for Real-time, Simultaneous Imaging of the TCR and its Associated Signaling Proteins
Published on: March 22, 2012
Atom interferometry with thousand-fold increase in dynamic range
Dimitry Yankelev1,2, Chen Avinadav3,2, Nir Davidson3
1Department of Physics of Complex Systems, Weizmann Institute of Science, Rehovot 7610001, Israel. dimitry.yankelev@weizmann.ac.il.
Scientists developed a new method to enhance the dynamic range of interferometry sensors without losing sensitivity. This technique uses two interferometers to create a larger measurement period, improving atom interferometer performance.
Area of Science:
- Quantum physics
- Metrology
- Sensor technology
Background:
- Interferometric sensors face a trade-off between sensitivity and dynamic range due to signal periodicity.
- Atom interferometers offer high sensitivity for gravito-inertial measurements but have limited dynamic range.
Purpose of the Study:
- To develop a methodology for extending the dynamic range of interferometry-based sensors.
- To maintain or improve sensitivity, stability, and bandwidth while increasing dynamic range.
Main Methods:
- Simultaneous operation of two nearly identical interferometers.
- Generating a moiré-like interference pattern with a period significantly larger than 2π.
- Utilizing common-mode noise suppression.
Main Results:
- Demonstrated a dynamic-range enhancement of over an order of magnitude in a single shot.
- Achieved over three orders of magnitude enhancement within a few shots.
- Verified performance for both static and dynamic signals in an atom interferometer.
Conclusions:
- The developed methodology substantially extends sensor dynamic range without compromising key performance metrics.
- This approach significantly improves atom interferometers and other interferometric sensors for challenging environments.
- The technique offers enhanced capabilities for measuring gravito-inertial forces under varied conditions.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Total Internal Reflection Fluorescence Microscopy
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Super-resolution Fluorescence Microscopy
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
IR Spectrometers

