Related Experiment Video
Updated: Nov 30, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
A gas chromatography-flame ionization detection method for direct and rapid determination of small molecule volatile
Jia Zhou1,2, Xiaoqing Lu1,2, Baoxia Tian1,2
1Faculty of Life Science and Food Engineering, HuaiYin Institute of Technology, Huaian, 223003 People's Republic of China.
Abstract:
It is still difficult to directly detect low content of volatile organic compounds (VOCs) in water samples by gas chromatography (GC) because when water is the only solvent, it would result in the instability and poor repeatability of peak retention time and peak shape. The adverse effects of water on direct GC analysis of VOCs cannot be significantly reduced or eliminated by simply changing the detection condition of GC. However, it was found that the addition of methanol in samples to a certain final proportion, such as 50 or 75% (v/v), could greatly reduce or eliminate the adverse effects of water. By using 75% (v/v) methanol as a solvent, the standard curves of ethanol, acetic acid, acetone, and isopropanol with correlation coefficient (R 2) over 0.99 were successfully plotted by gas chromatography-flame ionization detection (GC-FID) in a certain concentration range, respectively. The results showed that the retention time and peak shape stability of ethanol, acetic acid, acetone, and isopropanol in aqueous solution were greatly improved by the addition of methanol to final concertation of 75% (v/v). To verify the practical application potential of this method, the method was applied to the detection of components in isopropanol fermentation wastewater. The results showed that the method has well applicability and reliability. The key points in the application of this method were also summarized. This GC analysis method would have a wider and better application prospect in the detection of water-soluble organic matters.
More Related Videos
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Flame Photometry: Lab
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....