Longitudinal Micro-Computed Tomography Image Analysis for User-Defined Region of Interest in Critical-Sized Bone Defects
Published on: June 24, 2025
Quantification of Joint Space Width Difference on Radiography Via Phase-Only Correlation (POC) Analysis: a Phantom
Aimi Taguchi1, Shun Shishido1, Yafei Ou2
1Graduate School of Health Sciences, Hokkaido University, North-12 West-5, Kita-ku, Sapporo, 060-0812, Japan.
Abstract:
Several visual scoring methods are currently used to assess progression of rheumatoid arthritis (RA) on radiography. However, they are limited by its subjectivity and insufficient sensitivity. We have developed an original measurement system which uses a technique called phase-only correlation (POC). The purpose of this study is to validate the system by using a phantom simulating the joint of RA patients.A micrometer measurement apparatus that can adjust arbitrary joint space width (JSW) in a phantom joint was developed to define true JSW. The phantom was scanned with radiography, 320 multi detector CT (MDCT), high-resolution peripheral quantitative CT (HR-pQCT), cone beam CT (CBCT), and tomosynthesis. The width was adjusted to the average size of a women's metacarpophalangeal joint, from 1.2 to 2.2 mm with increments of 0.1 mm and 0.01 mm. Radiographical images were analyzed by the POC-based system and manual method, and images from various tomographical modalities were measured via the automatic margin detection method. Correlation coefficients between true JSW difference and measured JSW difference were all strong at 0.1 mm intervals with radiography (POC-based system and manual method), CBCT, 320MDCT, HR-pQCT, and tomosynthesis. At 0.01 mm intervals, radiography (POC-based system), 320MDCT, and HR-pQCT had strong correlations, while radiography (manual method) and CBCT had low correlations, and tomosynthesis had no statistically significant correlation. The smallest detectable changes for radiography (POC-based system), radiography (manual method), 320MDCT, HR-pQCT, CBCT, and tomosynthesis were 0.020 mm, 0.041 mm, 0.076 mm, 0.077 mm, 0.057 mm, and 0.087 mm, respectively. We conclude that radiography analyzed with the POC-based system might sensitively detect minute joint space changes of the finger joint.
More Related Videos
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
07:43In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET