Related Experiment Video
Updated: Nov 27, 2025

Utilizing Transcranial Magnetic Stimulation to Study the Human Neuromuscular System
Published on: January 20, 2012
Voluntary activation of knee extensor muscles with transcranial magnetic stimulation
James L Nuzzo1, David S Kennedy2, Harrison T Finn1
1Neuroscience Research Australia, Randwick, Australia.
Abstract:
We examined if transcranial magnetic stimulation (TMS) is a valid tool for assessment of voluntary activation of the knee extensors in healthy individuals. Maximal M-waves (Mmax) of vastus lateralis (VL) were evoked with electrical stimulation of femoral nerve (FNS); Mmax of medial hamstrings (HS) was evoked with electrical stimulation of sciatic nerve branches; motor evoked potentials (MEPs) of VL and HS were evoked with TMS; superimposed twitches (SIT) of knee extensors were evoked with FNS and TMS. In study 1, TMS intensity [69% output (SD: 5)] was optimized for MEP sizes, but guidelines for test validity could not be met. Agonist VL MEPs were too small [51.4% Mmax (SD: 11.9); guideline ≥70% Mmax] and antagonist HS MEPs were too big [16.5% Mmax (SD: 10.3); guideline <10% Mmax]. Consequently, the TMS estimated resting twitch [99.1 N (SD: 37.2)] and FNS resting twitch [142.4 N (SD: 41.8)] were different. In study 2, SITs at 90% maximal voluntary contraction (MVC) were similar between TMS [16.1 N (SD: 10.3)] and FNS [20.9 N (SD: 16.7)], when TMS intensity was optimized for this purpose, suggesting a procedure that combines TMS SITs with FNS resting twitches could be valid. In study 3, which tested the TMS intensity [56% output (SD: 18)] that evoked the largest SIT at 90% MVC, voluntary activation from TMS [87.3% (SD: 7.1)] and FNS [84.5% (SD: 7.6)] was different. In sum, the contemporary procedure for TMS-based voluntary activation of the knee extensors is invalid. A modified procedure improves validity but only in individuals who meet rigorous inclusion criteria for SITs and MEPs.NEW & NOTEWORTHY We discovered that the contemporary procedure for assessing voluntary activation of the knee extensor muscles with transcranial magnetic stimulation (TMS) is invalid. TMS activates too few agonist quadriceps motoneurons and too many antagonist hamstrings motoneurons to estimate the resting twitch accurately. A modified procedure, in which TMS-evoked superimposed twitches are considered together with the resting twitch from femoral nerve stimulation, is valid but only in select individuals who meet rigorous eligibility criteria.
More Related Videos
11:06Bilateral Assessment of the Corticospinal Pathways of the Ankle Muscles Using Navigated Transcranial Magnetic Stimulation
Published on: February 19, 2019
12:14Assessing Primary Motor Cortex Excitability and Excitability Modulation by Pairing Transcranial Magnetic Stimulation with Electromyography
Published on: October 7, 2025