Related Experiment Video
Updated: Nov 25, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Research on the NIQAS device for hazardous goods identification based on PGNAA technology
JiaTong Li1, WenBao Jia1, DaQian Hei2
1Institute of Nuclear Analytical Technology, College of Materials Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, 211106, China; Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Suzhou, 215000, China.
Abstract:
In the research, the Nuclide Identification and Quantitative Analysis System (NIQAS) for the identification of hazardous goods was designed and optimized by MCNP simulations. With the D-T neutron generator and HPGe detector set as the core of device, the modules, including reflector, moderator and shielding, etc., were optimized by a Signal-to-Noise Ratio (SNR) evaluation method. Moreover, the NIQAS device was set up for measuring the hazardous goods, and the type identification was discussed based on the established logical decision. Finally, a Graphical User Interface (GUI) was designed and the minimum detection time was further investigated.