Mitigation of Rebound Hyperglycemia With Real-Time Continuous Glucose Monitoring Data and Predictive Alerts
Giada Acciaroli1, John B Welsh1, Halis Kaan Akturk2
1Dexcom, Inc., San Diego, CA, USA.
Background:
Excess carbohydrate intake during hypoglycemia can lead to rebound hyperglycemia (RH). We investigated associations between RH and use of real-time continuous glucose monitoring (rtCGM) and an rtCGM system's predictive alert.
Methods:
RH events were series of sensor glucose values (SGVs) >180 mg/dL starting within two hours of an antecedent SGV <70 mg/dL. Events were characterized by their frequency, duration (consecutive SGVs >180 mg/dL × five minutes), and severity (area under the glucose concentration-time curve). To assess the impact of rtCGM, data gathered during the four-week baseline phase (without rtCGM) and four-week follow-up phase (with rtCGM) from 75 participants in the HypoDE clinical trial (NCT02671968) of hypoglycemia-unaware individuals were compared. To assess the impact of predictive alerts, we identified a convenience sample of 24 518 users of an rtCGM system without predictive alerts who transitioned to a system whose predictive alert signals an SGV ≤55 mg/dL within 20 minutes (Dexcom G5 and G6, respectively). RH events from periods of blinded versus unblinded rtCGM wear and from periods of G5 and G6 wear were compared with paired t tests.
Results:
Compared to RH events in the HypoDE baseline phase, the mean frequency, duration, and severity of events fell by 14%, 12%, and 23%, respectively, in the follow-up phase (all P < .05). Compared to RH events during G5 use, the mean frequency, duration, and severity of events fell by 7%, 8%, and 13%, respectively, during G6 use (all P < .001).
Conclusions:
Rebound hypreglycemia can be objectively quantified and mitigated with rtCGM and rtCGM-based predictive alerts.
Related Concept Videos
Hypoglycemia and Glucagon
Glucagon-like Receptor Agonists
GLP-1, when administered in high doses intravenously, triggers insulin secretion, inhibits glucagon release, slows gastric emptying, reduces food intake, and restores normal insulin secretion. However, its rapid inactivation by...
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Diabetes Mellitus: Type 2 and Gestational
Oral Hypoglycemic Agents: Biguanides and Glitazones
Oral Hypoglycemic Agents: Glinides