Increase in Fast Response Time of the Resistance-to-Voltage Converter When Monitoring the Cable Products' Insulation

Nikolay I Yermoshin1, Evgeny V Yakimov1, Aleksandr E Goldshtein1

  • 1School of Non-Destructive Testing, National Research Tomsk Polytechnic University, 30 Lenin Avenue, 634050 Tomsk, Russia.

Related Concept Videos

Insulation Coordination01:23

Insulation Coordination

Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
324
Resistance and Conductance01:25

Resistance and Conductance

A conductor's DC resistance at a given temperature is influenced by its resistivity, length, and cross-sectional area. Resistivity is an inherent property of the conductor material, with annealed copper serving as the international standard for measurement. For instance, the resistivity of hard-drawn aluminum at 20 degrees Celsius is 61% of the standard conductivity of annealed copper.
Various factors impact the resistance of a conductor. Spiraling in stranded conductors increases their...
253
Overcurrent Relays01:26

Overcurrent Relays

Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
351
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
314
Resistance01:19

Resistance

When a current moves through any conductor, the conductor causes some level of difficulty for the current to flow. The measure of that difficulty is known as the resistance of the material and is represented by R. Every material has its own resistance. In the case of conductors, heat is emitted whenever a current passes through them. Resistance depends on the resistivity of the material. Resistivity is a characteristic of the material used to fabricate electrical components, whereas the...
5.4K
Voltmeter01:18

Voltmeter

A voltmeter is an electrical device that measures the potential difference or voltage between two points. It is connected in parallel with the circuit element it is measuring. A parallel connection is used because elements in parallel experience the same potential difference. The voltmeter is represented by the symbol "V ".
An ideal voltmeter would have infinite resistance, so connecting it between two points in a circuit would not alter any of the currents. Real voltmeters always have...
2.2K