Purpose:
To show some preliminary results about the possibility to exploit a cardiovascular mathematical model-made patient-specific by noninvasive data routinely measured during ordinary clinical examinations-in order to obtain sufficiently accurate central blood pressure (BP) estimates.
Methods:
A closed-loop multiscale (0D and 1D) model of the cardiovascular system is made patient-specific by using as model inputs the individual mean heart rate and left-ventricular contraction time, weight, height, age, sex and mean/pulse brachial BPs. The resulting framework is used to determine central systolic, diastolic, mean and pulse pressures, which are compared with the beat-averaged invasive pressures of 12 patients aged 72 ± 6.61 years.
Results:
Errors in central systolic, diastolic, mean and pulse pressures by the model are 4.26 ± 2.81, 5.86 ± 4.38, 4.98 ± 3.95 and 3.51±2.38 mmHg, respectively.
Conclusion:
The proposed modeling approach shows a good patient-specific response and appears to be potentially useful in clinical practice. However, this approach needs to be evaluated in a larger cohort of patients and could possibly be improved through more accurate oscillometric BP measurement methods.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)