Related Experiment Video
Updated: Nov 20, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
An Evolving Clinical Need: Discordant Oxygenation Measurements of Intubated COVID-19 Patients
Jerry A Rubano1, Lauren M Maloney2,3, Jessica Simon4
1Division of Trauma, Emergency Surgery, Surgical Critical Care, Department of Surgery, HSC T18-040, Stony Brook Medicine, Stony Brook, NY, 11794, USA. Jerry.Rubano@stonybrookmedicine.edu.
Abstract:
Since the first appearance of the severe acute respiratory syndrome corona virus 2 (SARS-CoV-2) earlier this year, clinicians and researchers alike have been faced with dynamic, daily challenges of recognizing, understanding, and treating the coronavirus disease 2019 (COVID-19) due to SARS-CoV-2. Those who are moderately to severely ill with COVID-19 are likely to develop acute hypoxemic respiratory failure and require administration of supplemental oxygen. Assessing the need to initiate or titrate oxygen therapy is largely dependent on evaluating the patient's existing blood oxygenation status, either by direct arterial blood sampling or by transcutaneous arterial oxygen saturation monitoring, also referred to as pulse oximetry. While the sampling of arterial blood for measurement of dissolved gases provides a direct measurement, it is technically challenging to obtain, is painful to the patient, and can be time and resource intensive. Pulse oximetry allows for non-invasive, real-time, continuous monitoring of the percent of hemoglobin molecules that are saturated with oxygen, and usually closely predicts the arterial oxygen content. As such, it was particularly concerning when patients with severe COVID-19 requiring endotracheal intubation and mechanical ventilation within one of our intensive care units were observed to have significant discordance between their predicted arterial oxygen content via pulse oximetry and their actual measured oxygen content. We offer these preliminary observations along with our speculative causes as a timely, urgent clinical need. In the setting of a COVID-19 intensive care unit, entering a patient room to obtain a fresh arterial blood gas sample not only takes exponentially longer to do given the time required for donning and doffing of personal protective equipment (PPE), it involves the consumption of already sparce PPE, and it increases the risk of viral exposure to the nurse, physician, or respiratory therapist entering the room to obtain the sample. As such, technology similar to pulse oximetry which can be applied to a patients finger, and then continuously monitored from outside the room is essential in preventing a particularly dangerous situation of unrealized hypoxia in this critically-ill patient population. Additionally, it would appear that conventional two-wavelength pulse oximetry may not accurately predict the arterial oxygen content of blood in these patients. This discordance of oxygenation measurements poses a critical concern in the evaluation and management of the acute hypoxemic respiratory failure seen in patients with COVID-19.
More Related Videos
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:

