Using a Portable Near-infrared Spectroscopy Device to Estimate The Second Ventilatory Threshold
Víctor Rodrigo-Carranza1, Fernando González-Mohíno2,3, Anthony P Turner3
1Department of Physical Activity and Sports Sciences, Sport Training Lab, University of Castilla-La Mancha, Toledo, Spain.
A portable near-infrared spectroscopy (NIRS) device accurately identifies the exercise intensity breakpoint (StO2) comparable to the second ventilatory threshold (VT2) in runners. This validates NIRS for training intensity prescription above VT2.
Area of Science:
- Exercise Physiology
- Sports Science
- Biomedical Engineering
Background:
- The second ventilatory threshold (VT2) is a key indicator of exercise intensity.
- Near-infrared spectroscopy (NIRS) measures muscle oxygenation, potentially identifying physiological thresholds.
- Previous research linked NIRS-derived deoxygenated hemoglobin breakpoints to VT2 in healthy individuals.
Purpose of the Study:
- To investigate the association between the NIRS-derived oxygen saturation (StO2) breakpoint and VT2 in well-trained runners.
- To validate the use of portable NIRS devices for determining exercise intensity thresholds in a running context.
Main Methods:
- Ten well-trained runners underwent an incremental VO2max running test.
- Gas exchange and portable NIRS data (measuring StO2) were collected simultaneously.
- The StO2 breakpoint and VT2 were identified and compared based on %VO2max, speed, VO2, and %HRmax.
Main Results:
- No significant differences were found between the StO2 breakpoint and VT2 across measured parameters (%VO2max, speed, VO2, %HRmax).
- Strong, significant correlations (r=0.68 to 0.86, p<0.05) were observed between NIRS and gas exchange measures.
- Bland and Altman analysis showed good agreement between the NIRS breakpoint and VT2.
Conclusions:
- A portable NIRS device's StO2 breakpoint is a valid and comparable measure to VT2 determined by gas exchange in runners.
- Portable NIRS is suitable for identifying exercise training intensities above VT2 in running.
- This study provides the first validation of portable NIRS for threshold determination in running.
More Related Videos
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
08:44Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...