Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Prediction by statistical overlap theory of fraction of baseline occupied by chromatographic peaks
1Department of Chemistry and Biochemistry, Southern Illinois University at Carbondale, Carbondale, IL 62901-4409, USA.
Abstract:
The average minimum resolution required for separating adjacent single-component peaks (SCPs) in one-dimensional chromatograms is an important metric in statistical overlap theory (SOT). However, its value changes with changing chromatographic conditions in non-intuitive ways, when SOT predicts the average number of peaks (maxima). A more stable and easily understood value of resolution is obtained on making a different prediction. A general equation is derived for the sum of all separated and superposed widths of SCPs in a chromatogram. The equation is a function of the saturation α, a metric of chromatographic crowdedness, and is expressed in dimensionless form by dividing by the duration of the chromatogram. This dimensionless function, f(α), is also the cumulative distribution function of the probability of separating adjacent SCPs. Simulations based on the clustering of line segments representing SCPs verify expressions for f(α) calculated from five functions for the distribution of intervals between adjacent SCPs. Synthetic chromatograms are computed with different saturations, distributions of intervals, and distribution of SCP amplitudes. The chromatograms are analyzed by calculating the sum of the widths of peaks at different relative responses, dividing the sum by the duration of the chromatograms, and graphing the reduced sum against relative response. For small values of relative response, the reduced sum approaches the fraction of baseline that is occupied by chromatographic peaks. This fraction can be identified with f(α), if the saturation α is defined with the average minimum resolution equaling 1.5. The identification is general and is independent of the saturation, the interval distribution, or the amplitude distribution. This constant value of resolution corresponds to baseline resolution, which simplifies the interpretation of SOT.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
12:39A Novel Bayesian Change-point Algorithm for Genome-wide Analysis of Diverse ChIPseq Data Types
Published on: December 10, 2012
Related Concept Videos
Chromatographic Methods: Terminology
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...