Related Experiment Video
Updated: Nov 17, 2025

In-vivo Detection of Protein-protein Interactions on Micro-patterned Surfaces
Published on: March 19, 2010
High-Speed Lens-Free Holographic Sensing of Protein Molecules Using Quantitative Agglutination Assays
Zhen Xiong1, Colin J Potter1, Euan McLeod1
1Wyant College of Optical Sciences, University of Arizona, 1630 East University Boulevard, Tucson, Arizona 85719, United States.
Abstract:
Accurate, cost-effective, easy-to-use, and point-of-care sensors for protein biomarker levels are important for disease diagnostics. A cost-effective and compact readout approach that has been used for several diagnostic applications is lens-free holographic microscopy, which provides an ultralarge field of view and submicron resolution when it is coupled with pixel super-resolution techniques. Despite its potential as a diagnostic technique, lens-free microscopy has not previously been applied to quantitative protein molecule sensing in solution, which can simplify sensing protocols and ultimately enable measurements of binding kinetics in physiological conditions. Here, we sense interferon-γ (an immune system biomarker) and NeutrAvidin molecules in solution by combining lens-free microscopy with a one-step bead-based agglutination assay, enabled by a custom high-speed light-emitting diode (LED) array and automated image processing routines. We call this a quantitative large-area binding (QLAB) sensor. The high-speed light source provides, for the first time, pixel super-resolved imaging of >104 2 μm beads in solution undergoing Brownian motion, without significant motion blur. The automated image processing routines enable the counting of individual beads and clusters, providing a quantitative sensor readout that depends on both bead and analyte concentrations. Fits to the chemical binding theory are provided. For NeutrAvidin, we find a limit of detection (LOD) of <27 ng/mL (450 pM) and a dynamic range of 2-4 orders of magnitude. For mouse interferon-γ, the LOD is <3 ng/mL (200 pM) and the dynamic range is at least 4 orders of magnitude. The QLAB sensor holds promise for point-of-care applications in low-resource communities and where protocol simplicity is important.
More Related Videos
05:19Author Spotlight: Advancing Protein Glycosylation Research Using a Fully Automated System
Published on: June 28, 2024
08:22Calibration-free In Vitro Quantification of Protein Homo-oligomerization Using Commercial Instrumentation and Free, Open Source Brightness Analysis Software
Published on: July 17, 2018