Cutoff Value of Phase Angle by Bioelectrical Impedance Analysis at Admission as a Prognostic Factor in Patients with Acute Heart Failure
Published on: June 10, 2025
Agreement of bioelectrical resistance, reactance, and phase angle values from supine and standing bioimpedance
Jacob R Dellinger1, Baylor A Johnson1, Marqui L Benavides1
1Energy Balance & Body Composition Laboratory; Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, United States of America.
Abstract:
Objective. Bioimpedance devices are commonly used to assess health parameters and track changes in body composition. However, the cross-sectional agreement between different devices has not been conclusively established. Thus, the objective of this investigation was to examine the agreement between raw bioelectrical variables (resistance, reactance, and phase angle at the 50 kHz frequency) obtained from three bioimpedance analyzers.Approach. Healthy male (n = 76, mean ± SD; 33.8 ± 14.5 years; 83.9 ± 15.1 kg; 179.4 ± 6.9 cm) and female (n = 103, mean ± SD; 33.4 ± 15.9 years; 65.6 ± 12.1 kg; 164.9 ± 6.4 cm) participants completed assessments using three bioimpedance devices: supine bioimpedance spectroscopy (BIS), supine single-frequency bioelectrical impedance analysis (SFBIA), and standing multi-frequency bioelectrical impedance analysis (MFBIA). Differences in raw bioelectrical variables between the devices were quantified via one-way analysis of variance for the total sample and for each sex. Equivalence testing was used to determine equivalence between methods.Main results. Significant differences in all bioelectrical variables were observed between the three devices when examining the total sample and males only. The devices appeared to exhibit slightly better agreement when analyzing female participants only. Equivalence testing using the total sample as well as males and females separately revealed that resistance and phase angle were equivalent between the supine devices (BIS, SFBIA), but not with the standing analyzer (MFBIA).Significance. The present study demonstrated disagreement between different bioimpedance analyzers for quantifying raw bioelectrical variables, with the poorest agreement between devices that employed different body positions during testing. These results suggest that researchers and clinicians should employ device-specific reference values to classify participants based on raw bioelectrical variables, such as phase angle. If reference values are needed but are unavailable for a particular bioimpedance analyzer, the set of reference values produced using the most similar analyzer and reference population should be selected.
Related Concept Videos
Series Impedances: Three-Phase Line
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
RLC Series Circuits: Impedance
Thus, the magnitude of the impedance is given by the following equation,
Bode Plots Construction
Impedances and Admittance
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
Shunt Admittances
To model this effect, the method of images is employed. This method involves replacing the Earth with an image conductor that mirrors the original...
RLC Series Circuit: Problem-Solving
To solve the problem, first, determine the known and unknown quantities in the problem. Recalling the reactance equation for the inductor and capacitor and substituting the values,...