Related Experiment Video
Updated: Nov 16, 2025

Longitudinal Micro-Computed Tomography Image Analysis for User-Defined Region of Interest in Critical-Sized Bone Defects
Published on: June 24, 2025
Two-versus three-dimensional regions of interest for quantifying SPECT-CT images
Masakazu Tsujimoto1,2, Seiji Shirakawa3, Masanori Watanabe4
1Department of Radiology, Fujita Health University Hospital, Toyoake, Japan. mckz-t@fujita-hu.ac.jp.
Abstract:
The aim of this study was to investigate the relationship of quantitative parameters between the two-dimensional region of interest (ROI) and the three-dimensional volume of interest (VOI) for accumulation of radiopharmaceutical. Single-photon emission computed tomography combined with computed tomography (SPECT/CT) images of the NEMA/IEC phantom were acquired. The ROIs and VOIs were automatically set to the sphere and background in the phantom. We defined as two-dimensional analysis (2D analysis) that which used ROIs set on the center section of the sphere, and as three-dimensional analysis (3D analysis) that which used VOIs set on the center of gravity of the sphere. Dose linearity (DL), the recovery coefficient (RC), the contrast-to-noise ratio (CNR), and standardized uptake value (SUV) were evaluated. Each index value was compared between both analyses. DL was almost 1 under both conditions. RC showed a similar tendency with 2D and 3D analyses. The CNR for 3D analysis was smaller than for 2D analysis. The maximum SUV was almost equal with both analyses. The mean SUV with 3D analysis was underestimated by 4.83% on average compared with 2D analysis. For the same accumulation, a difference may occur in the quantitative index between 2 and 3D analyses. In particular, the quantitative parameters based on the average value tends to be smaller with 3D analysis than 2D analysis. The quantitative parameters in 2D analysis showed dependence upon the cross section used for setting the ROI, whereas 3D analysis showed less dependence on the position of the VOI.
More Related Videos
07:53Author Spotlight: Advancing 3D Modeling for Enhanced Diagnosis and Treatment of Pulmonary Nodules in Early-Stage Lung Cancer
Published on: October 13, 2023
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Two-Dimensional (2D) NMR: Overview