Related Experiment Video
Updated: Nov 16, 2025

Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
Initial setting of high-flow nasal oxygen post extubation based on mean inspiratory flow during a spontaneous
Sophia Butt1, Laura Pistidda2, Leda Floris2
1Department of Adult Critical Care, Guy's and St Thomas' NHS Foundation Trust, King's Health Partners, Division of Centre of Human Applied Physiological Sciences, King's College London, London, UK.
Purpose:
High flow nasal cannula (HFNC) is commonly used post-extubation in intensive care (ICU). Patients' comfort during HFNC is affected by flow rate. The study aims to describe the relationship between pre-extubation inspiratory flow requirements and the post-extubation flow rates on HFNC that maximises patient's comfort.
Methods:
This was an observational, retrospective study conducted in a university-affiliated ICU. We included patients extubated following successful spontaneous breathing trial (SBT). During the SBT we recorded variables including inspiratory flow. Patients who passed the SBT were extubated onto HFNC. HFNC was titrated from 20 L/min and increased in steps of 10 L/min, up to 60 L/min. At each step, patient's level of comfort was assessed. Fraction of inspired oxygen was titrated to maintain oxygen saturation 92-97%.
Results:
Nineteen participants were enrolled in the study. There was a significant positive correlation between mean inspiratory flow pre-extubation and the flow setting on HFNC which achieved the best comfort post-extubation (r2 0.88; p < 0.001). Overall, greatest comfort was observed for HFNC flows between 30 and 40 L/min but with individual variability.
Conclusion:
Measuring mean inspiratory flow during an SBT allows for individualised setting of HFNC flow rate immediately post-extubation and achieves the greatest comfort and interface tolerance.
More Related Videos
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation I: Indication and Settings
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...