Precision and accuracy of hyperglycemic clamps in a multicenter study
Kieren J Mather1, Ashley H Tjaden2, Adam Hoehn3
1Department of Medicine, School of Medicine, Indiana University, Indianapolis, Indiana.
Summary
Standardizing glucose clamp methods across multiple research centers is crucial. The Restoring Insulin Secretion (RISE) Consortium successfully implemented a hyperglycemic clamp protocol, achieving excellent precision and accuracy for glucose control in multicenter studies.
Area of Science:
- Endocrinology
- Metabolic Research
- Clinical Trial Methodology
Background:
- Glucose clamp studies are vital for metabolic research but face standardization challenges in multicenter settings.
- The Restoring Insulin Secretion (RISE) Consortium aimed to overcome these challenges for accurate insulin secretion assessment.
Purpose of the Study:
- To detail the methods used by the RISE Consortium to standardize hyperglycemic clamp procedures across seven study centers.
- To evaluate the precision, accuracy, and robustness of the standardized clamp protocol.
Main Methods:
- Implementation of a two-stage hyperglycemic clamp protocol with specific glucose targets (200 mg/dL and >450 mg/dL).
- Utilization of a centralized, spreadsheet-based algorithm to guide dextrose infusion rates based on real-time glucose measurements.
- Comprehensive training for clamp operators, coupled with ongoing performance surveillance and feedback.
Main Results:
- Achieved high overall precision (3%-9% variance) and accuracy (SD < 10%) in maintaining target glucose levels.
- Observed minor, statistically significant differences in glucose concentrations across centers, within technical variability.
- Demonstrated robustness of the method across diverse baseline physiology and on-study treatment effects.
Conclusions:
- The RISE Consortium's approach successfully standardized hyperglycemic clamp methodology across multiple centers, yielding excellent results.
- This standardized protocol provides a reliable framework for conducting multicenter glucose clamp studies.
More Related Videos
Related Concept Videos
Hypoglycemia and Glucagon
530
Without prolonged fasting, healthy individuals maintain blood glucose levels above 3.5 mM due to a well-adapted neuroendocrine counterregulatory system that effectively prevents acute hypoglycemia, a potentially life-threatening condition. The primary clinical scenarios for hypoglycemia encompass diabetes treatment, inappropriate production of endogenous insulin or insulin-like substances by tumors, and the use of glucose-lowering agents in non-diabetic individuals. Notably, hypoglycemia in the...
530
Diabetes: Symptoms, Diagnosis, and Complications
1.5K
For most patients, experiencing several weeks of polyuria, polydipsia, fatigue, and significant weight loss may indicate the presence of diabetes. Furthermore, adults displaying the phenotypic appearance of type 2 diabetes (particularly those who are obese and not initially insulin-requiring), may have islet cell autoantibodies, suggesting autoimmune-mediated β cell destruction and a diagnosis of latent autoimmune diabetes of adults (LADA). The categorization of glucose homeostasis is...
1.5K
Errors occurring during blood pressure monitoring
1.1K
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
1.1K